title: "Schneider Electric SCADAPack Smart RTU Series"
description: "High-performance smart remote terminal unit combining PLC logic execution with advanced telemetry, flow computing, and cybersecurity for remote operational assets."
canonical_url: "https://nodewave.net/store/automation/scadapack-rtu"
last_updated: "2026-10-04T04:04:23.883Z"
---

<note>

The **Schneider Electric SCADAPack Smart RTU** platform bridges the gap between traditional Remote Terminal Units and
high-performance Programmable Logic Controllers (PLCs). Using **RemoteConnect configuration software**, engineering
teams can build complex IEC 61131-3 logic while utilizing shared code blocks from Schneider Electric Modicon PLCs.

</note>

## Executive Summary and Core Capabilities

Schneider Electric SCADAPack Smart RTUs (featuring the **x70 generation**, including the **SCADAPack 47x and 57x**
series) are engineered for autonomous supervision and control of widely distributed infrastructure assets. Built with
dual-core processing architectures and low-power modes, these units handle local closed-loop logic execution while
storing up to 40,000 time-stamped events for transmission over low-bandwidth cellular or radio networks.

<callout color="green" icon="i-lucide-shield-check">

**Unified Control Architecture:** Standardizing on RemoteConnect enables engineering teams to import Derived Function
Blocks directly from EcoStruxure Control Expert (Unity Pro), simplifying code development across central plant PLCs and
remote field RTUs.

</callout>

<accordion>
<accordion-item icon="i-lucide-cpu" label="Operational Overview">

- **Autonomous Local Processing:** Continues executed automation logic and process control loops locally even during
communication link dropouts.
- **Integrated Flow Measurement:** Runs onboard **Realflo** applications to calculate standardized gas and liquid
volumes for up to 20 flow runs.
- **Conformal-Coated Ruggedness:** Designed to operate reliably in temperatures ranging from <span className="katex">
<span className="katex-mathml">
<math xmlns="http://www.w3.org/1998/Math/MathML">
<semantics>
<mrow>
<mo>

−

</mo>

<mn>

40

</mn>

<mtext>

°C

</mtext>
</mrow>

<annotation encoding="application/x-tex">

-40\text{ °C}

</annotation>
</semantics>
</math>
</span>

<span className="katex-html" ariaHidden="true">
<span className="base">
<span className="strut" style="height:0.7778em;vertical-align:-0.0833em;">



</span>

<span className="mord">

−

</span>

<span className="mord">

40

</span>

<span className="mord,text">
<span className="mord">

°C

</span>
</span>
</span>
</span>
</span>


to <span className="katex">
<span className="katex-mathml">
<math xmlns="http://www.w3.org/1998/Math/MathML">
<semantics>
<mrow>
<mo>

+

</mo>

<mn>

70

</mn>

<mtext>

°C

</mtext>
</mrow>

<annotation encoding="application/x-tex">

+70\text{ °C}

</annotation>
</semantics>
</math>
</span>

<span className="katex-html" ariaHidden="true">
<span className="base">
<span className="strut" style="height:0.7778em;vertical-align:-0.0833em;">



</span>

<span className="mord">

+

</span>

<span className="mord">

70

</span>

<span className="mord,text">
<span className="mord">

°C

</span>
</span>
</span>
</span>
</span>

 in harsh Class I, Div 2 hazardous environments.

</accordion-item>

<accordion-item icon="i-lucide-hard-drive" label="Hardware Architecture Deep-Dive">

The main CPU board incorporates a 500 MHz dual ARM Cortex-A7 processor paired with an ARM Cortex-M3 microcontroller to
process high-speed I/O updates and background communication tasks.

Hardware connectivity includes up to five serial ports (RS-232/RS-485), up to three Ethernet interfaces, USB host and
device interfaces, and modular expansion support via SCADAPack 6000 I/O modules and Modicon Edge I/O.

</accordion-item>
</accordion>

---

## Technical Specifications Matrix

<tabs>
<tabs-item label="Processing and Operating Software">
<table>
<thead>
  <tr>
    <th align="left">
      Parameter
    </th>
    
    <th align="left">
      Specification Details
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td align="left">
      <strong>
        System Processor
      </strong>
    </td>
    
    <td align="left">
      Dual ARM Cortex-A7 (500 MHz) and ARM Cortex-M3 coprocessor
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Configuration Tool
      </strong>
    </td>
    
    <td align="left">
      SCADAPack RemoteConnect (IEC 61131-3 logic engine)
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        EcoStruxure Compatibility
      </strong>
    </td>
    
    <td align="left">
      Code sharing and block importing from EcoStruxure Control Expert
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Event Buffer Memory
      </strong>
    </td>
    
    <td align="left">
      Up to 40,000 time-stamped events stored in non-volatile flash memory
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Embedded Applications
      </strong>
    </td>
    
    <td align="left">
      Realflo Multi-Run Flow Computer, Realift Artificial Lift Automation
    </td>
  </tr>
</tbody>
</table>
</tabs-item>

<tabs-item label="Communications and Fieldbus">
<table>
<thead>
  <tr>
    <th align="left">
      Communication Channel
    </th>
    
    <th align="left">
      Supported Capability
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td align="left">
      <strong>
        Industrial Protocols
      </strong>
    </td>
    
    <td align="left">
      DNP3 Level 4, Modbus RTU/TCP, IEC 60870-5-101/104
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Ethernet Interfaces
      </strong>
    </td>
    
    <td align="left">
      Up to 3x 10/100 Base-T RJ45 ports
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Serial Ports
      </strong>
    </td>
    
    <td align="left">
      Up to 5x serial interfaces (RS-232 / RS-485 selectable)
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        USB Connectivity
      </strong>
    </td>
    
    <td align="left">
      1x USB Host (Type-A), 1x USB Peripheral (Type-B or Type-C)
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Telemetry Support
      </strong>
    </td>
    
    <td align="left">
      Direct integration with Trio data radios, satellite terminals, and LTE modems
    </td>
  </tr>
</tbody>
</table>
</tabs-item>

<tabs-item label="Environmental and Electrical">
<table>
<thead>
  <tr>
    <th align="left">
      Metric
    </th>
    
    <th align="left">
      Certified Rating
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td align="left">
      <strong>
        Power Supply Input
      </strong>
    </td>
    
    <td align="left">
      <span className="katex">
        <span className="katex-mathml">
          <math xmlns="http://www.w3.org/1998/Math/MathML">
            <semantics>
              <mrow>
                <mn>
                  12
                </mn>
                
                <mtext>
                  to
                </mtext>
                
                <mn>
                  24
                </mn>
                
                <mtext>
                  VDC
                </mtext>
              </mrow>
              
              <annotation encoding="application/x-tex">
                12\text{ to }24\text{ VDC}
              </annotation>
            </semantics>
          </math>
        </span>
        
        <span className="katex-html" ariaHidden="true">
          <span className="base">
            <span className="strut" style="height:0.6833em;">
              
            </span>
            
            <span className="mord">
              12
            </span>
            
            <span className="mord,text">
              <span className="mord">
                to
              </span>
            </span>
            
            <span className="mord">
              24
            </span>
            
            <span className="mord,text">
              <span className="mord">
                VDC
              </span>
            </span>
          </span>
        </span>
      </span>
      
       operating range with low-power sleep modes
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Operating Temperature
      </strong>
    </td>
    
    <td align="left">
      <span className="katex">
        <span className="katex-mathml">
          <math xmlns="http://www.w3.org/1998/Math/MathML">
            <semantics>
              <mrow>
                <mo>
                  −
                </mo>
                
                <mn>
                  40
                </mn>
                
                <mtext>
                  °C to
                </mtext>
                
                <mo>
                  +
                </mo>
                
                <mn>
                  70
                </mn>
                
                <mtext>
                  °C
                </mtext>
              </mrow>
              
              <annotation encoding="application/x-tex">
                -40\text{ °C to }+70\text{ °C}
              </annotation>
            </semantics>
          </math>
        </span>
        
        <span className="katex-html" ariaHidden="true">
          <span className="base">
            <span className="strut" style="height:0.7778em;vertical-align:-0.0833em;">
              
            </span>
            
            <span className="mord">
              −
            </span>
            
            <span className="mord">
              40
            </span>
            
            <span className="mord,text">
              <span className="mord">
                °C to
              </span>
            </span>
            
            <span className="mspace" style="margin-right:0.2222em;">
              
            </span>
            
            <span className="mbin">
              +
            </span>
            
            <span className="mspace" style="margin-right:0.2222em;">
              
            </span>
          </span>
          
          <span className="base">
            <span className="strut" style="height:0.6944em;">
              
            </span>
            
            <span className="mord">
              70
            </span>
            
            <span className="mord,text">
              <span className="mord">
                °C
              </span>
            </span>
          </span>
        </span>
      </span>
      
       (<span className="katex">
        <span className="katex-mathml">
          <math xmlns="http://www.w3.org/1998/Math/MathML">
            <semantics>
              <mrow>
                <mo>
                  −
                </mo>
                
                <mn>
                  40
                </mn>
                
                <mtext>
                  °F to
                </mtext>
                
                <mo>
                  +
                </mo>
                
                <mn>
                  158
                </mn>
                
                <mtext>
                  °F
                </mtext>
              </mrow>
              
              <annotation encoding="application/x-tex">
                -40\text{ °F to }+158\text{ °F}
              </annotation>
            </semantics>
          </math>
        </span>
        
        <span className="katex-html" ariaHidden="true">
          <span className="base">
            <span className="strut" style="height:0.7778em;vertical-align:-0.0833em;">
              
            </span>
            
            <span className="mord">
              −
            </span>
            
            <span className="mord">
              40
            </span>
            
            <span className="mord,text">
              <span className="mord">
                °F to
              </span>
            </span>
            
            <span className="mspace" style="margin-right:0.2222em;">
              
            </span>
            
            <span className="mbin">
              +
            </span>
            
            <span className="mspace" style="margin-right:0.2222em;">
              
            </span>
          </span>
          
          <span className="base">
            <span className="strut" style="height:0.6944em;">
              
            </span>
            
            <span className="mord">
              158
            </span>
            
            <span className="mord,text">
              <span className="mord">
                °F
              </span>
            </span>
          </span>
        </span>
      </span>
      
      )
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Hazardous Area Approvals
      </strong>
    </td>
    
    <td align="left">
      Class I, Division 2, Groups A, B, C, D / Zone 2 certified
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Board Protection
      </strong>
    </td>
    
    <td align="left">
      Conformal coating for moisture and atmospheric contaminant protection
    </td>
  </tr>
  
  <tr>
    <td align="left">
      <strong>
        Enclosure Mounting
      </strong>
    </td>
    
    <td align="left">
      Standard DIN rail mounting or direct panel mounting
    </td>
  </tr>
</tbody>
</table>
</tabs-item>
</tabs>

---

## Target Industry Applications

<card-group>
<card icon="i-lucide-droplets" title="Water and Wastewater Networks">

Monitors district metering areas, controls booster pump stations, and tracks remote reservoir water levels.

</card>

<card icon="i-lucide-flame" title="Oil and Gas Midstream Telemetry">

Delivers custody-transfer flow calculations, wellhead plunger lift optimization, and pipeline leak surveillance.

</card>
</card-group>

---

## External Resources and Documentation

Access official documentation, software links, and datasheets from Schneider Electric:

<card-group>
<card icon="i-lucide-external-link" title="Official Schneider Electric Smart RTU Hub" target="_blank" to="https://www.se.com/us/en/product-subcategory/6040-smart-rtu/">

Access product selection tools, firmware downloads, and technical manuals directly from Schneider Electric.

</card>

<card icon="i-lucide-file-text" title="SCADAPack x70 Technical Documentation" target="_blank" to="https://www.se.com/in/en/download/document/SCADAPack_470_474_RTUs_DS_A4/">

Download detailed hardware installation manuals, wiring diagrams, and protocol implementation guides.

</card>
</card-group>