[{"data":1,"prerenderedAt":820},["ShallowReactive",2],{"store-product-automation\u002Fscadapack-rtu":3,"store-surround-scadapack-rtu":808,"store-related-SE-SCADAPACK-X70":819},{"id":4,"title":5,"_path":6,"anchors":7,"badge":17,"body":18,"category":703,"categoryDescription":704,"categoryIcon":70,"compareAtPrice":6,"compatibility":705,"currency":710,"date":711,"description":712,"downloads":713,"draft":725,"excerpt":6,"extension":726,"featured":725,"gallery":727,"highlights":736,"image":743,"inStock":744,"lastUpdated":745,"meta":746,"navigation":744,"path":752,"price":753,"seo":754,"sku":757,"specs":758,"stem":794,"tags":795,"useCases":802,"version":6,"__hash__":807},"store\u002Fstore\u002Fautomation\u002Fscadapack-rtu.md","Schneider Electric SCADAPack Smart RTU Series",null,[8,13],{"label":9,"icon":10,"to":11,"target":12},"Official Schneider Electric Smart RTU Portal","i-lucide-external-link","https:\u002F\u002Fwww.se.com\u002Fus\u002Fen\u002Fproduct-subcategory\u002F6040-smart-rtu\u002F","_blank",{"label":14,"icon":15,"to":16,"target":12},"EcoStruxure Geo SCADA Expert Overview","i-lucide-book-open","https:\u002F\u002Fwww.se.com\u002Fus\u002Fen\u002Fwork\u002Fproducts\u002Findustrial-automation-and-control\u002F","Industrial Telemetry",{"type":19,"value":20,"toc":694},"minimark",[21,37,42,53,64,218,221,225,645,647,651,669,671,675,678],[22,23,24],"note",{},[25,26,27,28,32,33,36],"p",{},"The ",[29,30,31],"strong",{},"Schneider Electric SCADAPack Smart RTU"," platform bridges the gap between traditional Remote Terminal Units and\nhigh-performance Programmable Logic Controllers (PLCs). Using ",[29,34,35],{},"RemoteConnect configuration software",", engineering\nteams can build complex IEC 61131-3 logic while utilizing shared code blocks from Schneider Electric Modicon PLCs.",[38,39,41],"h2",{"id":40},"executive-summary-and-core-capabilities","Executive Summary and Core Capabilities",[25,43,44,45,48,49,52],{},"Schneider Electric SCADAPack Smart RTUs (featuring the ",[29,46,47],{},"x70 generation",", including the ",[29,50,51],{},"SCADAPack 47x and 57x","\nseries) are engineered for autonomous supervision and control of widely distributed infrastructure assets. Built with\ndual-core processing architectures and low-power modes, these units handle local closed-loop logic execution while\nstoring up to 40,000 time-stamped events for transmission over low-bandwidth cellular or radio networks.",[54,55,58],"callout",{"color":56,"icon":57},"green","i-lucide-shield-check",[25,59,60,63],{},[29,61,62],{},"Unified Control Architecture:"," Standardizing on RemoteConnect enables engineering teams to import Derived Function\nBlocks directly from EcoStruxure Control Expert (Unity Pro), simplifying code development across central plant PLCs and\nremote field RTUs.",[65,66,67,208],"accordion",{},[68,69,72],"accordion-item",{"icon":70,"label":71},"i-lucide-cpu","Operational Overview",[73,74,75,82,92],"ul",{},[76,77,78,81],"li",{},[29,79,80],{},"Autonomous Local Processing:"," Continues executed automation logic and process control loops locally even during\ncommunication link dropouts.",[76,83,84,87,88,91],{},[29,85,86],{},"Integrated Flow Measurement:"," Runs onboard ",[29,89,90],{},"Realflo"," applications to calculate standardized gas and liquid\nvolumes for up to 20 flow runs.",[76,93,94,97,98,162,163,207],{},[29,95,96],{},"Conformal-Coated Ruggedness:"," Designed to operate reliably in temperatures ranging from ",[99,100,103,134],"span",{"className":101},[102],"katex",[99,104,107],{"className":105},[106],"katex-mathml",[108,109,111],"math",{"xmlns":110},"http:\u002F\u002Fwww.w3.org\u002F1998\u002FMath\u002FMathML",[112,113,114,129],"semantics",{},[115,116,117,121,125],"mrow",{},[118,119,120],"mo",{},"−",[122,123,124],"mn",{},"40",[126,127,128],"mtext",{}," °C",[130,131,133],"annotation",{"encoding":132},"application\u002Fx-tex","-40\\text{ °C}",[99,135,139],{"className":136,"ariaHidden":138},[137],"katex-html","true",[99,140,143,148,152,155],{"className":141},[142],"base",[99,144],{"className":145,"style":147},[146],"strut","height:0.7778em;vertical-align:-0.0833em;",[99,149,120],{"className":150},[151],"mord",[99,153,124],{"className":154},[151],[99,156,159],{"className":157},[151,158],"text",[99,160,128],{"className":161},[151],"\nto ",[99,164,166,186],{"className":165},[102],[99,167,169],{"className":168},[106],[108,170,171],{"xmlns":110},[112,172,173,183],{},[115,174,175,178,181],{},[118,176,177],{},"+",[122,179,180],{},"70",[126,182,128],{},[130,184,185],{"encoding":132},"+70\\text{ °C}",[99,187,189],{"className":188,"ariaHidden":138},[137],[99,190,192,195,198,201],{"className":191},[142],[99,193],{"className":194,"style":147},[146],[99,196,177],{"className":197},[151],[99,199,180],{"className":200},[151],[99,202,204],{"className":203},[151,158],[99,205,128],{"className":206},[151]," in harsh Class I, Div 2 hazardous environments.",[68,209,212,215],{"icon":210,"label":211},"i-lucide-hard-drive","Hardware Architecture Deep-Dive",[25,213,214],{},"The main CPU board incorporates a 500 MHz dual ARM Cortex-A7 processor paired with an ARM Cortex-M3 microcontroller to\nprocess high-speed I\u002FO updates and background communication tasks.",[25,216,217],{},"Hardware connectivity includes up to five serial ports (RS-232\u002FRS-485), up to three Ethernet interfaces, USB host and\ndevice interfaces, and modular expansion support via SCADAPack 6000 I\u002FO modules and Modicon Edge I\u002FO.",[219,220],"hr",{},[38,222,224],{"id":223},"technical-specifications-matrix","Technical Specifications Matrix",[226,227,228,303,370],"tabs",{},[229,230,232],"tabs-item",{"label":231},"Processing and Operating Software",[233,234,235,249],"table",{},[236,237,238],"thead",{},[239,240,241,246],"tr",{},[242,243,245],"th",{"align":244},"left","Parameter",[242,247,248],{"align":244},"Specification Details",[250,251,252,263,273,283,293],"tbody",{},[239,253,254,260],{},[255,256,257],"td",{"align":244},[29,258,259],{},"System Processor",[255,261,262],{"align":244},"Dual ARM Cortex-A7 (500 MHz) and ARM Cortex-M3 coprocessor",[239,264,265,270],{},[255,266,267],{"align":244},[29,268,269],{},"Configuration Tool",[255,271,272],{"align":244},"SCADAPack RemoteConnect (IEC 61131-3 logic engine)",[239,274,275,280],{},[255,276,277],{"align":244},[29,278,279],{},"EcoStruxure Compatibility",[255,281,282],{"align":244},"Code sharing and block importing from EcoStruxure Control Expert",[239,284,285,290],{},[255,286,287],{"align":244},[29,288,289],{},"Event Buffer Memory",[255,291,292],{"align":244},"Up to 40,000 time-stamped events stored in non-volatile flash memory",[239,294,295,300],{},[255,296,297],{"align":244},[29,298,299],{},"Embedded Applications",[255,301,302],{"align":244},"Realflo Multi-Run Flow Computer, Realift Artificial Lift Automation",[229,304,306],{"label":305},"Communications and Fieldbus",[233,307,308,318],{},[236,309,310],{},[239,311,312,315],{},[242,313,314],{"align":244},"Communication Channel",[242,316,317],{"align":244},"Supported Capability",[250,319,320,330,340,350,360],{},[239,321,322,327],{},[255,323,324],{"align":244},[29,325,326],{},"Industrial Protocols",[255,328,329],{"align":244},"DNP3 Level 4, Modbus RTU\u002FTCP, IEC 60870-5-101\u002F104",[239,331,332,337],{},[255,333,334],{"align":244},[29,335,336],{},"Ethernet Interfaces",[255,338,339],{"align":244},"Up to 3x 10\u002F100 Base-T RJ45 ports",[239,341,342,347],{},[255,343,344],{"align":244},[29,345,346],{},"Serial Ports",[255,348,349],{"align":244},"Up to 5x serial interfaces (RS-232 \u002F RS-485 selectable)",[239,351,352,357],{},[255,353,354],{"align":244},[29,355,356],{},"USB Connectivity",[255,358,359],{"align":244},"1x USB Host (Type-A), 1x USB Peripheral (Type-B or Type-C)",[239,361,362,367],{},[255,363,364],{"align":244},[29,365,366],{},"Telemetry Support",[255,368,369],{"align":244},"Direct integration with Trio data radios, satellite terminals, and LTE modems",[229,371,373],{"label":372},"Environmental and Electrical",[233,374,375,385],{},[236,376,377],{},[239,378,379,382],{},[242,380,381],{"align":244},"Metric",[242,383,384],{"align":244},"Certified Rating",[250,386,387,452,615,625,635],{},[239,388,389,394],{},[255,390,391],{"align":244},[29,392,393],{},"Power Supply Input",[255,395,396,451],{"align":244},[99,397,399,423],{"className":398},[102],[99,400,402],{"className":401},[106],[108,403,404],{"xmlns":110},[112,405,406,420],{},[115,407,408,411,414,417],{},[122,409,410],{},"12",[126,412,413],{}," to ",[122,415,416],{},"24",[126,418,419],{}," VDC",[130,421,422],{"encoding":132},"12\\text{ to }24\\text{ VDC}",[99,424,426],{"className":425,"ariaHidden":138},[137],[99,427,429,433,436,442,445],{"className":428},[142],[99,430],{"className":431,"style":432},[146],"height:0.6833em;",[99,434,410],{"className":435},[151],[99,437,439],{"className":438},[151,158],[99,440,413],{"className":441},[151],[99,443,416],{"className":444},[151],[99,446,448],{"className":447},[151,158],[99,449,419],{"className":450},[151]," operating range with low-power sleep modes",[239,453,454,459],{},[255,455,456],{"align":244},[29,457,458],{},"Operating Temperature",[255,460,461,538,539,614],{"align":244},[99,462,464,489],{"className":463},[102],[99,465,467],{"className":466},[106],[108,468,469],{"xmlns":110},[112,470,471,486],{},[115,472,473,475,477,480,482,484],{},[118,474,120],{},[122,476,124],{},[126,478,479],{}," °C to ",[118,481,177],{},[122,483,180],{},[126,485,128],{},[130,487,488],{"encoding":132},"-40\\text{ °C to }+70\\text{ °C}",[99,490,492,522],{"className":491,"ariaHidden":138},[137],[99,493,495,498,501,504,510,515,519],{"className":494},[142],[99,496],{"className":497,"style":147},[146],[99,499,120],{"className":500},[151],[99,502,124],{"className":503},[151],[99,505,507],{"className":506},[151,158],[99,508,479],{"className":509},[151],[99,511],{"className":512,"style":514},[513],"mspace","margin-right:0.2222em;",[99,516,177],{"className":517},[518],"mbin",[99,520],{"className":521,"style":514},[513],[99,523,525,529,532],{"className":524},[142],[99,526],{"className":527,"style":528},[146],"height:0.6944em;",[99,530,180],{"className":531},[151],[99,533,535],{"className":534},[151,158],[99,536,128],{"className":537},[151]," (",[99,540,542,569],{"className":541},[102],[99,543,545],{"className":544},[106],[108,546,547],{"xmlns":110},[112,548,549,566],{},[115,550,551,553,555,558,560,563],{},[118,552,120],{},[122,554,124],{},[126,556,557],{}," °F to ",[118,559,177],{},[122,561,562],{},"158",[126,564,565],{}," °F",[130,567,568],{"encoding":132},"-40\\text{ °F to }+158\\text{ °F}",[99,570,572,599],{"className":571,"ariaHidden":138},[137],[99,573,575,578,581,584,590,593,596],{"className":574},[142],[99,576],{"className":577,"style":147},[146],[99,579,120],{"className":580},[151],[99,582,124],{"className":583},[151],[99,585,587],{"className":586},[151,158],[99,588,557],{"className":589},[151],[99,591],{"className":592,"style":514},[513],[99,594,177],{"className":595},[518],[99,597],{"className":598,"style":514},[513],[99,600,602,605,608],{"className":601},[142],[99,603],{"className":604,"style":528},[146],[99,606,562],{"className":607},[151],[99,609,611],{"className":610},[151,158],[99,612,565],{"className":613},[151],")",[239,616,617,622],{},[255,618,619],{"align":244},[29,620,621],{},"Hazardous Area Approvals",[255,623,624],{"align":244},"Class I, Division 2, Groups A, B, C, D \u002F Zone 2 certified",[239,626,627,632],{},[255,628,629],{"align":244},[29,630,631],{},"Board Protection",[255,633,634],{"align":244},"Conformal coating for moisture and atmospheric contaminant protection",[239,636,637,642],{},[255,638,639],{"align":244},[29,640,641],{},"Enclosure Mounting",[255,643,644],{"align":244},"Standard DIN rail mounting or direct panel mounting",[219,646],{},[38,648,650],{"id":649},"target-industry-applications","Target Industry Applications",[652,653,654,662],"card-group",{},[655,656,659],"card",{"icon":657,"title":658},"i-lucide-droplets","Water and Wastewater Networks",[25,660,661],{},"Monitors district metering areas, controls booster pump stations, and tracks remote reservoir water levels.",[655,663,666],{"icon":664,"title":665},"i-lucide-flame","Oil and Gas Midstream Telemetry",[25,667,668],{},"Delivers custody-transfer flow calculations, wellhead plunger lift optimization, and pipeline leak surveillance.",[219,670],{},[38,672,674],{"id":673},"external-resources-and-documentation","External Resources and Documentation",[25,676,677],{},"Access official documentation, software links, and datasheets from Schneider Electric:",[652,679,680,686],{},[655,681,683],{"icon":10,"title":682,"target":12,"to":11},"Official Schneider Electric Smart RTU Hub",[25,684,685],{},"Access product selection tools, firmware downloads, and technical manuals directly from Schneider Electric.",[655,687,691],{"icon":688,"title":689,"target":12,"to":690},"i-lucide-file-text","SCADAPack x70 Technical Documentation","https:\u002F\u002Fwww.se.com\u002Fin\u002Fen\u002Fdownload\u002Fdocument\u002FSCADAPack_470_474_RTUs_DS_A4\u002F",[25,692,693],{},"Download detailed hardware installation manuals, wiring diagrams, and protocol implementation guides.",{"title":695,"searchDepth":696,"depth":696,"links":697},"",3,[698,700,701,702],{"id":40,"depth":699,"text":41},2,{"id":223,"depth":699,"text":224},{"id":649,"depth":699,"text":650},{"id":673,"depth":699,"text":674},"Industrial Automation and Telemetry","Rugged remote terminal units, programmable automation controllers, and telemetry systems engineered for remote infrastructure monitoring.",[706,707,708,709],"EcoStruxure Geo SCADA Expert (ClearSCADA)","Modicon Edge I\u002FO and SCADAPack 6000 Expansion Modules","EcoStruxure Control Expert (Unity Pro)","Trio Data Radios and Cellular Modem Gateways","USD","2026-09-26T00:00:00Z","High-performance smart remote terminal unit combining PLC logic execution with advanced telemetry, flow computing, and cybersecurity for remote operational assets.",[714,720],{"name":715,"url":716,"type":717,"format":718,"size":719},"Schneider Electric SCADAPack x70 Family Brochure","\u002Fstore\u002Fautomation\u002Fscadapack-rtu\u002Fbrochure-scadapack-x70.pdf","Datasheet","pdf","3.1 MB",{"name":721,"url":722,"type":723,"format":718,"size":724},"SCADAPack RemoteConnect Software User Manual","\u002Fstore\u002Fautomation\u002Fscadapack-rtu\u002Fmanual-remoteconnect-scadapack.pdf","Manual","8.4 MB",false,"md",[728,732],{"src":729,"alt":730,"caption":731},"\u002Fstore\u002Fautomation\u002Fscadapack-rtu\u002Fgallery-1.png","Schneider Electric SCADAPack x70 Series controller showing removable I\u002FO terminal blocks","Compact DIN rail housing featuring conformal-coated electronics and versatile serial\u002FEthernet ports",{"src":733,"alt":734,"caption":735},"\u002Fstore\u002Fautomation\u002Fscadapack-rtu\u002Fgallery-2.png","SCADAPack Smart RTU installed in an outdoor wellhead control cabinet","Ruggedized deployment for remote oil and gas pipeline and water infrastructure telemetry",[737,738,739,740,741,742],"Combines IEC 61131-3 logic programming with event-driven telemetry and high-capacity local data logging","Powered by high-performance ARM Cortex dual-core processors running RemoteConnect configuration software","Shared logic environment with EcoStruxure Control Expert for code reuse across Modicon PLCs and RTUs","Native support for industrial protocols including DNP3 Level 4, Modbus RTU\u002FTCP, and IEC 60870-5-101\u002F104","Built-in application modules for Realflo gas and liquid flow computing and Realift artificial lift","Hardened construction certified for Class I, Division 2 \u002F Zone 2 hazardous areas with wide thermal tolerance","\u002Fstore\u002Fautomation\u002Fscadapack-rtu\u002Fimage.png",true,"2026-09-30T18:11:00Z",{"readingTime":747},{"text":748,"minutes":749,"time":750,"words":751},"3 min read",2.19,131400,438,"\u002Fstore\u002Fautomation\u002Fscadapack-rtu",0,{"title":755,"description":756},"Schneider Electric SCADAPack Smart RTU | NodeWave","Explore Schneider Electric SCADAPack Smart RTUs. Combining PLC control power with DNP3 telemetry, Realflo computing, and RemoteConnect software.","SE-SCADAPACK-X70",[759,763,766,769,773,775,778,782,785,788,791],{"category":760,"label":761,"value":762},"Processing and Logic System","Main CPU Architecture","Dual ARM Cortex-A7 (500 MHz) plus dedicated ARM Cortex-M3 core",{"category":760,"label":764,"value":765},"Logic Programming Software","RemoteConnect (IEC 61131-3 logic, Function Block, Ladder Logic, Structured Text)",{"category":760,"label":767,"value":768},"PLC Logic Reuse","Direct importing of EcoStruxure Control Expert logic blocks",{"category":770,"label":771,"value":772},"Communications and Protocols","Supported Open Protocols","DNP3 (Level 4 Outstation\u002FPeer-to-Peer), Modbus RTU\u002FTCP, IEC 60870-5-101\u002F104",{"category":770,"label":346,"value":774},"Up to 5 serial communication ports (RS-232 \u002F RS-485 configurable)",{"category":770,"label":776,"value":777},"Network and USB Ports","1x or 3x 10\u002F100 Mbps Ethernet ports, USB Host (Type-A), USB Device (Type-C or Type-B)",{"category":779,"label":780,"value":781},"I\u002FO and Embedded Functions","Onboard I\u002FO Options","Up to 20 Digital Inputs, 12 Digital Outputs, 8 Analog Inputs, 2 Analog Outputs",{"category":779,"label":783,"value":784},"Specialized Applications","Realflo Flow Computer (up to 20 flow runs), Realift artificial lift control",{"category":372,"label":458,"value":786,"unit":787},"-40 to +70","°C",{"category":372,"label":789,"value":790},"Hazardous Area Ratings","Class I, Division 2, Groups A, B, C, D and ATEX\u002FIECEx Zone 2 certified",{"category":372,"label":792,"value":793},"Circuit Protection","Conformal-coated circuit boards for corrosion and moisture resistance","store\u002Fautomation\u002Fscadapack-rtu",[796,797,798,799,800,801],"Schneider Electric","SCADAPack","Smart RTU","RemoteConnect","DNP3 \u002F Modbus","EcoStruxure",[803,804,805,806],"Water and Wastewater Pipeline Monitoring, Leak Detection, and Pumping Station Control","Oil and Gas Midstream Wellhead Automation and Realflo Custody Transfer Measurement","Electrical Distribution Substation Monitoring and Remote Power Grid Telemetry","Environmental Monitoring and Remote Weather Data Acquisition Stations","sK2lT1_VOxbZrnMKMqJN1gt7nHtiMGS3VpMpfXYW9GQ",[809,814],{"title":810,"path":811,"stem":812,"description":813,"children":-1},"IMAGO VisionBox AI Edge Appliance","\u002Fstore\u002Fai-vision\u002Fimago-visionbox-ai","store\u002Fai-vision\u002Fimago-visionbox-ai","High-performance embedded AI vision system powered by NVIDIA Jetson AGX Orin, featuring an integrated Real-Time Communication Controller (RTCC) for microsecond-accurate industrial automation.",{"title":815,"path":816,"stem":817,"description":818,"children":-1},"NodeWave 1.2kWh Backup Power Generator (B254KE)","\u002Fstore\u002Fbatteries\u002F12000wh-battery","store\u002Fbatteries\u002F12000wh-battery","Locally engineered 1.2kWh (1,200Wh) Lithium Polymer backup battery generator featuring an integrated 600W inverter, universal AC output, XT60 solar charge port, and digital LED status display. Built in Kenya.",[],1791086643131]