[{"data":1,"prerenderedAt":3112},["ShallowReactive",2],{"store-product-networking\u002Fcisco-catalyst-ie3400":3,"store-surround-cisco-catalyst-ie3400":1074,"store-related-CSCO-CAT-IE3400":1085},{"id":4,"title":5,"_path":6,"anchors":7,"badge":17,"body":18,"category":969,"categoryDescription":970,"categoryIcon":126,"compareAtPrice":6,"compatibility":971,"currency":976,"date":977,"description":978,"downloads":979,"draft":991,"excerpt":6,"extension":992,"featured":991,"gallery":993,"highlights":1002,"image":1009,"inStock":1010,"lastUpdated":1011,"meta":1012,"navigation":1010,"path":1018,"price":6,"seo":1019,"sku":1022,"specs":1023,"stem":1061,"tags":1062,"useCases":1068,"version":6,"__hash__":1073},"store\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400.md","Cisco Catalyst IE3400 Heavy Duty Switch",null,[8,13],{"label":9,"icon":10,"to":11,"target":12},"Official Cisco Catalyst IE3400 Product Page","i-lucide-external-link","https:\u002F\u002Fwww.cisco.com\u002Fc\u002Fen\u002Fus\u002Fproducts\u002Fswitches\u002Fcatalyst-ie3400-rugged-series-switches\u002Findex.html","_blank",{"label":14,"icon":15,"to":16,"target":12},"Cisco Industrial Ethernet Switch Portfolio","i-lucide-book-open","https:\u002F\u002Fwww.cisco.com\u002Fc\u002Fen\u002Fus\u002Fproducts\u002Fswitches\u002Findustrial-ethernet-switches\u002Findex.html","DCS Backbone Ready",{"type":19,"value":20,"toc":960},"minimark",[21,40,45,109,120,348,351,355,911,913,917,935,937,941,944],[22,23,24],"note",{},[25,26,27,28,31,32,35,36,39],"p",{},"The ",[29,30,5],"strong",{}," is built for mission-critical ",[29,33,34],{},"Distributed Control System (DCS)\nplatforms",". Running ",[29,37,38],{},"Cisco IOS XE",", this modular DIN-rail switch provides full Gigabit performance, ultra-low\nlatency, and up to 26 high-density ports to prevent signal bottlenecks across automated plant environments.",[41,42,44],"h2",{"id":43},"executive-summary-and-core-capabilities","Executive Summary and Core Capabilities",[25,46,27,47,50,51,108],{},[29,48,49],{},"Cisco Catalyst IE3400 Rugged Series"," brings intent-based enterprise networking directly to severe factory floor\nenvironments. Designed with modular expansion capabilities, the IE3400 scales up to 26 Gigabit ports and supports\nhigh-density Power over Ethernet Plus (PoE+) up to ",[52,53,56,83],"span",{"className":54},[55],"katex",[52,57,60],{"className":58},[59],"katex-mathml",[61,62,64],"math",{"xmlns":63},"http:\u002F\u002Fwww.w3.org\u002F1998\u002FMath\u002FMathML",[65,66,67,78],"semantics",{},[68,69,70,74],"mrow",{},[71,72,73],"mn",{},"480",[75,76,77],"mtext",{}," W",[79,80,82],"annotation",{"encoding":81},"application\u002Fx-tex","480\\text{ W}",[52,84,88],{"className":85,"ariaHidden":87},[86],"katex-html","true",[52,89,92,97,101],{"className":90},[91],"base",[52,93],{"className":94,"style":96},[95],"strut","height:0.6833em;",[52,98,73],{"className":99},[100],"mord",[52,102,105],{"className":103},[100,104],"text",[52,106,77],{"className":107},[100],", delivering non-blocking line-rate performance for\ndeterministic DCS communications.",[110,111,114],"callout",{"color":112,"icon":113},"green","i-lucide-shield-check",[25,115,116,119],{},[29,117,118],{},"Enterprise Policy at the Edge:"," By running Cisco IOS XE, the IE3400 extends security policies, Cisco Catalyst Center\n(DNA Center) automation, and zero-trust port isolation directly to field-level I\u002FO racks and DCS controllers.",[121,122,123,150],"accordion",{},[124,125,128],"accordion-item",{"icon":126,"label":127},"i-lucide-network","Operational Overview",[129,130,131,138,144],"ul",{},[132,133,134,137],"li",{},[29,135,136],{},"High-Density Modular Expansion:"," Expand from a compact 10-port base system up to 26 ports using copper, SFP fiber,\nor PoE+ expansion modules.",[132,139,140,143],{},[29,141,142],{},"Ultra-Low Latency Determinism:"," Supports IEEE 1588v2 Precision Time Protocol (PTP), CIP EtherNet\u002FIP, and PROFINET\nQoS for real-time fieldbus synchronization.",[132,145,146,149],{},[29,147,148],{},"Resilient Ring Failover:"," Features Cisco Resilient Ethernet Protocol (REP) and Spanning Tree protocols (MSTP\u002FRSTP)\nfor sub-second network link recovery.",[124,151,154,250],{"icon":152,"label":153},"i-lucide-cpu","Hardware Architecture Deep-Dive",[25,155,156,157,204,205,249],{},"The IE3400 utilizes a fanless, convection-cooled aluminum enclosure designed for extreme operating conditions\nbetween ",[52,158,160,182],{"className":159},[55],[52,161,163],{"className":162},[59],[61,164,165],{"xmlns":63},[65,166,167,179],{},[68,168,169,173,176],{},[170,171,172],"mo",{},"−",[71,174,175],{},"40",[75,177,178],{}," °C",[79,180,181],{"encoding":81},"-40\\text{ °C}",[52,183,185],{"className":184,"ariaHidden":87},[86],[52,186,188,192,195,198],{"className":187},[91],[52,189],{"className":190,"style":191},[95],"height:0.7778em;vertical-align:-0.0833em;",[52,193,172],{"className":194},[100],[52,196,175],{"className":197},[100],[52,199,201],{"className":200},[100,104],[52,202,178],{"className":203},[100]," and ",[52,206,208,228],{"className":207},[55],[52,209,211],{"className":210},[59],[61,212,213],{"xmlns":63},[65,214,215,225],{},[68,216,217,220,223],{},[170,218,219],{},"+",[71,221,222],{},"70",[75,224,178],{},[79,226,227],{"encoding":81},"+70\\text{ °C}",[52,229,231],{"className":230,"ariaHidden":87},[86],[52,232,234,237,240,243],{"className":233},[91],[52,235],{"className":236,"style":191},[95],[52,238,219],{"className":239},[100],[52,241,222],{"className":242},[100],[52,244,246],{"className":245},[100,104],[52,247,178],{"className":248},[100],". The base system packs eight Gigabit RJ45 downlinks and two Gigabit SFP\nuplink slots.",[25,251,252,253,292,293,347],{},"Equipped with ",[52,254,256,274],{"className":255},[55],[52,257,259],{"className":258},[59],[61,260,261],{"xmlns":63},[65,262,263,271],{},[68,264,265,268],{},[71,266,267],{},"4",[75,269,270],{}," GB",[79,272,273],{"encoding":81},"4\\text{ GB}",[52,275,277],{"className":276,"ariaHidden":87},[86],[52,278,280,283,286],{"className":279},[91],[52,281],{"className":282,"style":96},[95],[52,284,267],{"className":285},[100],[52,287,289],{"className":288},[100,104],[52,290,270],{"className":291},[100]," DRAM, hardware-based Secure Unique Device Identifier (SUDI) chips, and dual terminal blocks\nfor ",[52,294,296,320],{"className":295},[55],[52,297,299],{"className":298},[59],[61,300,301],{"xmlns":63},[65,302,303,317],{},[68,304,305,308,311,314],{},[71,306,307],{},"9.6",[75,309,310],{}," to ",[71,312,313],{},"60",[75,315,316],{}," VDC",[79,318,319],{"encoding":81},"9.6\\text{ to }60\\text{ VDC}",[52,321,323],{"className":322,"ariaHidden":87},[86],[52,324,326,329,332,338,341],{"className":325},[91],[52,327],{"className":328,"style":96},[95],[52,330,307],{"className":331},[100],[52,333,335],{"className":334},[100,104],[52,336,310],{"className":337},[100],[52,339,313],{"className":340},[100],[52,342,344],{"className":343},[100,104],[52,345,316],{"className":346},[100]," power inputs, the switch provides zero-downtime operation for demanding industrial\narchitectures.",[349,350],"hr",{},[41,352,354],{"id":353},"technical-specifications-matrix","Technical Specifications Matrix",[356,357,358,433,500],"tabs",{},[359,360,362],"tabs-item",{"label":361},"Switching Performance and OS",[363,364,365,379],"table",{},[366,367,368],"thead",{},[369,370,371,376],"tr",{},[372,373,375],"th",{"align":374},"left","Parameter",[372,377,378],{"align":374},"Specification Details",[380,381,382,393,403,413,423],"tbody",{},[369,383,384,390],{},[385,386,387],"td",{"align":374},[29,388,389],{},"System Operating System",[385,391,392],{"align":374},"Cisco IOS XE (Network Essentials or Network Advantage)",[369,394,395,400],{},[385,396,397],{"align":374},[29,398,399],{},"Base Port Setup",[385,401,402],{"align":374},"8x 10\u002F100\u002F1000 Mbps RJ45 ports + 2x 100\u002F1000 SFP uplinks",[369,404,405,410],{},[385,406,407],{"align":374},[29,408,409],{},"Maximum System Capacity",[385,411,412],{"align":374},"Up to 26 Gigabit Ethernet ports via 1 expansion module",[369,414,415,420],{},[385,416,417],{"align":374},[29,418,419],{},"PoE Capability",[385,421,422],{"align":374},"Up to 24 ports PoE\u002FPoE+ (30 W per port, 480 W max budget)",[369,424,425,430],{},[385,426,427],{"align":374},[29,428,429],{},"System Memory",[385,431,432],{"align":374},"4 GB DRAM",[359,434,436],{"label":435},"Industrial Features and Security",[363,437,438,448],{},[366,439,440],{},[369,441,442,445],{},[372,443,444],{"align":374},"Feature",[372,446,447],{"align":374},"Standard Support",[380,449,450,460,470,480,490],{},[369,451,452,457],{},[385,453,454],{"align":374},[29,455,456],{},"Industrial Protocols",[385,458,459],{"align":374},"CIP EtherNet\u002FIP, PROFINET v2, Modbus TCP, GOOSE messaging",[369,461,462,467],{},[385,463,464],{"align":374},[29,465,466],{},"Precision Timing",[385,468,469],{"align":374},"IEEE 1588v2 PTP (Precision Time Protocol)",[369,471,472,477],{},[385,473,474],{"align":374},[29,475,476],{},"Cybersecurity Baseline",[385,478,479],{"align":374},"IEEE 802.1X, MACsec, Port Security, TACACS+, RADIUS, SUDI 2099",[369,481,482,487],{},[385,483,484],{"align":374},[29,485,486],{},"Network Visibility",[385,488,489],{"align":374},"Flexible NetFlow (FNF), SPAN\u002FRSPAN, SNMPv3, Syslog",[369,491,492,497],{},[385,493,494],{"align":374},[29,495,496],{},"Management Platforms",[385,498,499],{"align":374},"Cisco Catalyst Center, Cisco Industrial Network Director (IND)",[359,501,503],{"label":502},"Electrical and Environmental",[363,504,505,515],{},[366,506,507],{},[369,508,509,512],{},[372,510,511],{"align":374},"Metric",[372,513,514],{"align":374},"Rating Standard",[380,516,517,579,666,716,901],{},[369,518,519,524],{},[385,520,521],{"align":374},[29,522,523],{},"Input Voltage Range",[385,525,526,578],{"align":374},[52,527,529,551],{"className":528},[55],[52,530,532],{"className":531},[59],[61,533,534],{"xmlns":63},[65,535,536,548],{},[68,537,538,540,543,545],{},[71,539,307],{},[75,541,542],{}," V to ",[71,544,313],{},[75,546,547],{}," V DC",[79,549,550],{"encoding":81},"9.6\\text{ V to }60\\text{ V DC}",[52,552,554],{"className":553,"ariaHidden":87},[86],[52,555,557,560,563,569,572],{"className":556},[91],[52,558],{"className":559,"style":96},[95],[52,561,307],{"className":562},[100],[52,564,566],{"className":565},[100,104],[52,567,542],{"className":568},[100],[52,570,313],{"className":571},[100],[52,573,575],{"className":574},[100,104],[52,576,547],{"className":577},[100]," redundant terminal block inputs",[369,580,581,586],{},[385,582,583],{"align":374},[29,584,585],{},"Operating Temperature",[385,587,588,665],{"align":374},[52,589,591,616],{"className":590},[55],[52,592,594],{"className":593},[59],[61,595,596],{"xmlns":63},[65,597,598,613],{},[68,599,600,602,604,607,609,611],{},[170,601,172],{},[71,603,175],{},[75,605,606],{}," °C to ",[170,608,219],{},[71,610,222],{},[75,612,178],{},[79,614,615],{"encoding":81},"-40\\text{ °C to }+70\\text{ °C}",[52,617,619,649],{"className":618,"ariaHidden":87},[86],[52,620,622,625,628,631,637,642,646],{"className":621},[91],[52,623],{"className":624,"style":191},[95],[52,626,172],{"className":627},[100],[52,629,175],{"className":630},[100],[52,632,634],{"className":633},[100,104],[52,635,606],{"className":636},[100],[52,638],{"className":639,"style":641},[640],"mspace","margin-right:0.2222em;",[52,643,219],{"className":644},[645],"mbin",[52,647],{"className":648,"style":641},[640],[52,650,652,656,659],{"className":651},[91],[52,653],{"className":654,"style":655},[95],"height:0.6944em;",[52,657,222],{"className":658},[100],[52,660,662],{"className":661},[100,104],[52,663,178],{"className":664},[100]," (Sealed\u002Fvented cabinet certified)",[369,667,668,673],{},[385,669,670],{"align":374},[29,671,672],{},"Shock and Vibration",[385,674,675,676,715],{"align":374},"IEC 60068-2-27 (",[52,677,679,697],{"className":678},[55],[52,680,682],{"className":681},[59],[61,683,684],{"xmlns":63},[65,685,686,694],{},[68,687,688,691],{},[71,689,690],{},"50",[75,692,693],{}," G",[79,695,696],{"encoding":81},"50\\text{ G}",[52,698,700],{"className":699,"ariaHidden":87},[86],[52,701,703,706,709],{"className":702},[91],[52,704],{"className":705,"style":96},[95],[52,707,690],{"className":708},[100],[52,710,712],{"className":711},[100,104],[52,713,693],{"className":714},[100]," operational shock) \u002F IEC 60068-2-64",[369,717,718,723],{},[385,719,720],{"align":374},[29,721,722],{},"Dimensions (WxDxH)",[385,724,725,813,814,900],{"align":374},[52,726,728,757],{"className":727},[55],[52,729,731],{"className":730},[59],[61,732,733],{"xmlns":63},[65,734,735,754],{},[68,736,737,740,743,746,748,751],{},[71,738,739],{},"152",[170,741,742],{},"×",[71,744,745],{},"91",[170,747,742],{},[71,749,750],{},"135",[75,752,753],{}," mm",[79,755,756],{"encoding":81},"152\\times 91\\times 135\\text{ mm}",[52,758,760,779,797],{"className":759,"ariaHidden":87},[86],[52,761,763,767,770,773,776],{"className":762},[91],[52,764],{"className":765,"style":766},[95],"height:0.7278em;vertical-align:-0.0833em;",[52,768,739],{"className":769},[100],[52,771],{"className":772,"style":641},[640],[52,774,742],{"className":775},[645],[52,777],{"className":778,"style":641},[640],[52,780,782,785,788,791,794],{"className":781},[91],[52,783],{"className":784,"style":766},[95],[52,786,745],{"className":787},[100],[52,789],{"className":790,"style":641},[640],[52,792,742],{"className":793},[645],[52,795],{"className":796,"style":641},[640],[52,798,800,804,807],{"className":799},[91],[52,801],{"className":802,"style":803},[95],"height:0.6444em;",[52,805,750],{"className":806},[100],[52,808,810],{"className":809},[100,104],[52,811,753],{"className":812},[100]," (",[52,815,817,845],{"className":816},[55],[52,818,820],{"className":819},[59],[61,821,822],{"xmlns":63},[65,823,824,842],{},[68,825,826,829,831,834,836,839],{},[71,827,828],{},"6.0",[170,830,742],{},[71,832,833],{},"3.6",[170,835,742],{},[71,837,838],{},"5.3",[75,840,841],{}," in",[79,843,844],{"encoding":81},"6.0\\times 3.6\\times 5.3\\text{ in}",[52,846,848,866,884],{"className":847,"ariaHidden":87},[86],[52,849,851,854,857,860,863],{"className":850},[91],[52,852],{"className":853,"style":766},[95],[52,855,828],{"className":856},[100],[52,858],{"className":859,"style":641},[640],[52,861,742],{"className":862},[645],[52,864],{"className":865,"style":641},[640],[52,867,869,872,875,878,881],{"className":868},[91],[52,870],{"className":871,"style":766},[95],[52,873,833],{"className":874},[100],[52,876],{"className":877,"style":641},[640],[52,879,742],{"className":880},[645],[52,882],{"className":883,"style":641},[640],[52,885,887,891,894],{"className":886},[91],[52,888],{"className":889,"style":890},[95],"height:0.6679em;",[52,892,838],{"className":893},[100],[52,895,897],{"className":896},[100,104],[52,898,841],{"className":899},[100],")",[369,902,903,908],{},[385,904,905],{"align":374},[29,906,907],{},"Compliance",[385,909,910],{"align":374},"UL\u002FIEC 61010-2-201, UL\u002FIEC 62368-1, Class I Div 2 \u002F Zone 2",[349,912],{},[41,914,916],{"id":915},"target-industry-applications","Target Industry Applications",[918,919,920,928],"card-group",{},[921,922,925],"card",{"icon":923,"title":924},"i-lucide-activity","Plant DCS Infrastructure",[25,926,927],{},"Acts as the central, low-latency Gigabit backbone connecting Distributed Control System (DCS) process nodes.",[921,929,932],{"icon":930,"title":931},"i-lucide-zap","Substation and Power Automation",[25,933,934],{},"Delivers real-time GOOSE messaging and IEEE 1588 time synchronization across high-EMC utility bays.",[349,936],{},[41,938,940],{"id":939},"external-resources-and-documentation","External Resources and Documentation",[25,942,943],{},"Access official documentation, datasheets, and software tools directly from Cisco:",[918,945,946,952],{},[921,947,949],{"icon":10,"title":948,"target":12,"to":11},"Official Cisco Catalyst IE3400 Portal",[25,950,951],{},"Explore ordering guides, expansion module combinations, and licensing options.",[921,953,957],{"icon":954,"title":955,"target":12,"to":956},"i-lucide-file-text","Cisco Catalyst IE3400 Datasheet Document","https:\u002F\u002Fwww.cisco.com\u002Fc\u002Fen\u002Fus\u002Fproducts\u002Fcollateral\u002Fswitches\u002Fcatalyst-ie3400-rugged-series-switches\u002Fdatasheet-c78-741910.html",[25,958,959],{},"Review complete technical specifications, power supply guides, and mounting accessories.",{"title":961,"searchDepth":962,"depth":962,"links":963},"",3,[964,966,967,968],{"id":43,"depth":965,"text":44},2,{"id":353,"depth":965,"text":354},{"id":915,"depth":965,"text":916},{"id":939,"depth":965,"text":940},"Industrial Networking and Managed Switches","Hardened Layer 2 and Layer 3 managed Ethernet switches engineered for high electromagnetic interference and mission-critical automation loops.",[972,973,974,975],"Cisco Catalyst Center (formerly DNA Center) and Cisco Industrial Network Director (IND)","Cisco IEM-3300 and IEM-3400 Series Copper and Fiber Expansion Modules","Standard CIP EtherNet\u002FIP, PROFINET IO, and Modbus TCP Controllers","Standard 35 mm DIN Rail and Wall Mounting Assemblies","USD","2026-09-26T00:00:00Z","High-density modular DIN-rail industrial switch delivering secure, high-bandwidth, and low-latency network backbones for DCS platforms.",[980,986],{"name":981,"url":982,"type":983,"format":984,"size":985},"Cisco Catalyst IE3400 Series Official Datasheet","\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fdatasheet-cisco-ie3400.pdf","Datasheet","pdf","2.1 MB",{"name":987,"url":988,"type":989,"format":984,"size":990},"Cisco Catalyst IE3400 Hardware Installation Guide","\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fmanual-cisco-ie3400.pdf","Manual","5.8 MB",false,"md",[994,998],{"src":995,"alt":996,"caption":997},"\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fgallery-1.png","Cisco Catalyst IE3400 base unit front panel featuring Gigabit RJ45 ports and SFP uplinks","Ruggedized DIN rail housing featuring full Gigabit throughput and Cisco IOS XE execution",{"src":999,"alt":1000,"caption":1001},"\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fgallery-2.png","Cisco Catalyst IE3400 extended with an expansion module inside a DCS cabinet","Modular chassis expansion providing up to 26 ports with up to 480 W PoE power budget",[1003,1004,1005,1006,1007,1008],"Modular DIN-rail chassis expandable up to 26 full Gigabit ports with copper and SFP fiber options","Driven by programmable Cisco IOS XE with intent-based networking and automated Cisco DNA Center management","Delivers up to 24 ports of High-Density PoE\u002FPoE+ (30 W per port) with a total power budget up to 480 W","Ultra-low latency determinism certified for CIP EtherNet\u002FIP, PROFINET v2, and IEEE 1588v2 PTP time synchronization","Hardened fanless construction operating reliably across extreme industrial temperatures from -40 °C to 70 °C","Enterprise-grade cybersecurity featuring MACsec, IEEE 802.1X, Trust Anchor, and Flexible NetFlow (FNF)","\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fimage.png",true,"2026-10-01T07:46:00Z",{"readingTime":1013},{"text":1014,"minutes":1015,"time":1016,"words":1017},"3 min read",2.085,125100,417,"\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400",{"title":1020,"description":1021},"Cisco Catalyst IE3400 Heavy Duty Switch | NodeWave","Explore the Cisco Catalyst IE3400 Heavy Duty Switch. Advanced modular DIN-rail switch with full Gigabit speed, Cisco IOS XE, 480W PoE+, and low-latency DCS support.","CSCO-CAT-IE3400",[1024,1028,1031,1034,1037,1041,1044,1048,1051,1055,1058],{"category":1025,"label":1026,"value":1027},"Port and Modular Expansion","Base Port Configuration","8x 10\u002F100\u002F1000Base-T RJ45 ports + 2x 100\u002F1000 SFP uplink slots",{"category":1025,"label":1029,"value":1030},"Maximum Port Capacity","Expandable up to 26 Gigabit ports using 1 expansion module slot",{"category":1025,"label":1032,"value":1033},"Power over Ethernet (PoE)","Up to 24x IEEE 802.3at PoE+ ports (up to 480 W total budget)",{"category":1035,"label":1036,"value":392},"Performance and Operating Software","Operating System Software",{"category":1038,"label":1039,"value":1040},"Performance and Operating System","Switching Capacity and Memory","Line-rate non-blocking switching | 4 GB DRAM | 2 GB Flash",{"category":1038,"label":1042,"value":1043},"Real-Time Protocols","CIP EtherNet\u002FIP, PROFINET v2, Modbus TCP, IEEE 1588v2 PTP",{"category":1045,"label":1046,"value":1047},"Network Security and Monitoring","Cybersecurity Protocols","MACsec, 802.1X, Port Security, Dynamic ARP Inspection, TACACS+, RADIUS",{"category":1045,"label":1049,"value":1050},"Redundancy Technologies","Resilient Ethernet Protocol (REP) ring, MSTP, RSTP, EtherChannel",{"category":1052,"label":1053,"value":1054},"Power and Mechanical Specifications","Input Power Range","Dual redundant 9.6 V to 60 V DC input via terminal blocks",{"category":1052,"label":1056,"value":1057},"Dimensions and Weight","152 x 91 x 135 mm (6.0 x 3.6 x 5.3 in) | 1.7 kg (3.75 lbs)",{"category":1052,"label":585,"value":1059,"unit":1060},"-40 to +70","°C","store\u002Fnetworking\u002Fcisco-catalyst-ie3400",[1063,1064,1065,1066,38,1067],"Cisco","Catalyst IE3400","Managed Switch","Gigabit Ethernet","DCS Platform",[1069,1070,1071,1072],"Distributed Control System (DCS) Plant High-Availability Network Backbones","Power Substation Automation with GOOSE Messaging and IEEE 1588 Precision Timing","High-Density Video Surveillance and Security Camera Deployments","Factory Automation Processing High-Volume Field Loops and Control Networks","9JkVQT-2qsKAY7YGmFmeJkWC6LnHumlhH2pc0YwhOHU",[1075,1080],{"title":1076,"path":1077,"stem":1078,"description":1079,"children":-1},"VEGAPULS 6X Radar Level Sensor","\u002Fstore\u002Finstrumentation\u002Fvegapuls-6x","store\u002Finstrumentation\u002Fvegapuls-6x","Universal 80 GHz continuous non-contact radar level sensor engineered by VEGA for extreme process conditions, high-temperature chemical reactors, and high-pressure vessels.",{"title":1081,"path":1082,"stem":1083,"description":1084,"children":-1},"Cisco Catalyst IR1101 Rugged Router","\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ir1101","store\u002Fnetworking\u002Fcisco-catalyst-ir1101","Highly modular industrial edge router delivering secure IPsec routing and cellular 5G uplink capabilities across extended operational corridors.",[1086,1690],{"id":1087,"title":1088,"_path":6,"anchors":1089,"badge":1096,"body":1097,"category":969,"categoryDescription":1598,"categoryIcon":126,"compareAtPrice":6,"compatibility":1599,"currency":976,"date":977,"description":1604,"downloads":1605,"draft":991,"excerpt":6,"extension":992,"featured":991,"gallery":1614,"highlights":1623,"image":1630,"inStock":1010,"lastUpdated":1631,"meta":1632,"navigation":1010,"path":1637,"price":6,"seo":1638,"sku":1641,"specs":1642,"stem":1676,"tags":1677,"useCases":1684,"version":6,"__hash__":1689},"store\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch.md","Hirschmann Ethernet-APL & Fiber Industrial Switches",[1090,1093],{"label":1091,"icon":10,"to":1092,"target":12},"Official Belden Hirschmann Brand Hub","https:\u002F\u002Fwww.belden.com\u002Fabout\u002Fconnected-brands\u002Fhirschmann",{"label":1094,"icon":15,"to":1095,"target":12},"Belden Industrial Managed Switches Portfolio","https:\u002F\u002Fwww.belden.com\u002Fproducts\u002Findustrial-networking-cybersecurity\u002Fmanaged-switches","Ex Zone & Ethernet-APL Ready",{"type":19,"value":1098,"toc":1592},[1099,1119,1121,1223,1231,1351,1353,1355,1552,1554,1556,1571,1573,1575,1578],[22,1100,1101],{},[25,1102,27,1103,1106,1107,1110,1111,1114,1115,1118],{},[29,1104,1105],{},"Hirschmann Ethernet-APL Field Switches"," (alongside the ",[29,1108,1109],{},"BOBCAT and Managed Modular Series",") extend high-speed\nIP communication directly into ",[29,1112,1113],{},"explosion-proof process environments",". By utilizing ",[29,1116,1117],{},"Ethernet Advanced Physical\nLayer (Ethernet-APL)"," and 10BASE-T1L single-pair technology, these switches eliminate legacy fieldbus gateways in\nhazardous chemical and oil & gas facilities.",[41,1120,44],{"id":43},[25,1122,1123,1124,1164,1165,1222],{},"Engineered by Belden Hirschmann, these switches deliver intrinsically safe communication to Zone 0, 1, and 2 hazardous\nareas. Combining high-speed fiber-optic uplinks with single-pair Ethernet field spurs, they deliver ",[52,1125,1127,1145],{"className":1126},[55],[52,1128,1130],{"className":1129},[59],[61,1131,1132],{"xmlns":63},[65,1133,1134,1142],{},[68,1135,1136,1139],{},[71,1137,1138],{},"10",[75,1140,1141],{}," Mbps",[79,1143,1144],{"encoding":81},"10\\text{ Mbps}",[52,1146,1148],{"className":1147,"ariaHidden":87},[86],[52,1149,1151,1155,1158],{"className":1150},[91],[52,1152],{"className":1153,"style":1154},[95],"height:0.8889em;vertical-align:-0.1944em;",[52,1156,1138],{"className":1157},[100],[52,1159,1161],{"className":1160},[100,104],[52,1162,1141],{"className":1163},[100],"\nsimultaneous power and data over 2-wire cabling up to ",[52,1166,1168,1192],{"className":1167},[55],[52,1169,1171],{"className":1170},[59],[61,1172,1173],{"xmlns":63},[65,1174,1175,1189],{},[68,1176,1177,1180,1183,1186],{},[71,1178,1179],{},"1",[170,1181,1182],{"separator":87},",",[71,1184,1185],{},"000",[75,1187,1188],{}," meters",[79,1190,1191],{"encoding":81},"1,000\\text{ meters}",[52,1193,1195],{"className":1194,"ariaHidden":87},[86],[52,1196,1198,1202,1205,1209,1213,1216],{"className":1197},[91],[52,1199],{"className":1200,"style":1201},[95],"height:0.8389em;vertical-align:-0.1944em;",[52,1203,1179],{"className":1204},[100],[52,1206,1182],{"className":1207},[1208],"mpunct",[52,1210],{"className":1211,"style":1212},[640],"margin-right:0.1667em;",[52,1214,1185],{"className":1215},[100],[52,1217,1219],{"className":1218},[100,104],[52,1220,1188],{"className":1221},[100],", unlocking real-time asset analytics without\nrisking electrical ignition in explosive atmosphere loops.",[110,1224,1225],{"color":112,"icon":113},[25,1226,1227,1230],{},[29,1228,1229],{},"Direct-to-Field IP Digitization:"," Ethernet-APL brings native TCP\u002FIP protocols (PROFINET, EtherNet\u002FIP, HART-IP)\ndirectly to hazardous field instruments in Zone 0, replacing slow 4-20mA analog loops with high-bandwidth diagnostic\nchannels.",[121,1232,1233,1255],{},[124,1234,1235],{"icon":126,"label":127},[129,1236,1237,1243,1249],{},[132,1238,1239,1242],{},[29,1240,1241],{},"Intrinsically Safe Ex Field Spurs:"," Delivers Ex ia \u002F Ex ic field connections, allowing safe hot-swapping and wiring\nof instruments in explosive gas and dust environments.",[132,1244,1245,1248],{},[29,1246,1247],{},"High-Integrity Fiber Backbones:"," Fast SFP\u002FST\u002FSC optical interfaces extend network links across kilometers of\nhigh-EMC plant territory.",[132,1250,1251,1254],{},[29,1252,1253],{},"HiOS Industrial Software:"," Runs Hirschmann HiOS firmware, featuring sub-20 ms HiPER Ring redundancy and\nTime-Sensitive Networking (TSN) for deterministic loop timing.",[124,1256,1257,1344],{"icon":152,"label":153},[25,1258,1259,1260,1301,1302,1343],{},"Housed in ruggedized IP30 or IP67 die-cast aluminum enclosures, the switch features conformal-coated PCB assemblies\nresistant to corrosive gases and thermal extremes ranging from ",[52,1261,1263,1280],{"className":1262},[55],[52,1264,1266],{"className":1265},[59],[61,1267,1268],{"xmlns":63},[65,1269,1270,1278],{},[68,1271,1272,1274,1276],{},[170,1273,172],{},[71,1275,175],{},[75,1277,178],{},[79,1279,181],{"encoding":81},[52,1281,1283],{"className":1282,"ariaHidden":87},[86],[52,1284,1286,1289,1292,1295],{"className":1285},[91],[52,1287],{"className":1288,"style":191},[95],[52,1290,172],{"className":1291},[100],[52,1293,175],{"className":1294},[100],[52,1296,1298],{"className":1297},[100,104],[52,1299,178],{"className":1300},[100]," to ",[52,1303,1305,1322],{"className":1304},[55],[52,1306,1308],{"className":1307},[59],[61,1309,1310],{"xmlns":63},[65,1311,1312,1320],{},[68,1313,1314,1316,1318],{},[170,1315,219],{},[71,1317,222],{},[75,1319,178],{},[79,1321,227],{"encoding":81},[52,1323,1325],{"className":1324,"ariaHidden":87},[86],[52,1326,1328,1331,1334,1337],{"className":1327},[91],[52,1329],{"className":1330,"style":191},[95],[52,1332,219],{"className":1333},[100],[52,1335,222],{"className":1336},[100],[52,1338,1340],{"className":1339},[100,104],[52,1341,178],{"className":1342},[100],".",[25,1345,1346,1347,1350],{},"The architecture provides high isolation between system power supplies, fiber trunk interfaces, and APL field spur\ncircuits. Built-in diagnostic LEDs, relay contact outputs, and integration with ",[29,1348,1349],{},"Hirschmann Industrial HiVision"," allow\nproactive network monitoring from central control rooms.",[349,1352],{},[41,1354,354],{"id":353},[356,1356,1357,1422,1489],{},[359,1358,1360],{"label":1359},"Ethernet-APL and Network Interfaces",[363,1361,1362,1370],{},[366,1363,1364],{},[369,1365,1366,1368],{},[372,1367,375],{"align":374},[372,1369,378],{"align":374},[380,1371,1372,1382,1392,1402,1412],{},[369,1373,1374,1379],{},[385,1375,1376],{"align":374},[29,1377,1378],{},"Field Layer Standard",[385,1380,1381],{"align":374},"Ethernet-APL (10BASE-T1L, IEEE 802.3cg compliant)",[369,1383,1384,1389],{},[385,1385,1386],{"align":374},[29,1387,1388],{},"Field Spur Port Count",[385,1390,1391],{"align":374},"Up to 16x 2-wire SPE ports supporting combined power + data",[369,1393,1394,1399],{},[385,1395,1396],{"align":374},[29,1397,1398],{},"Maximum Spur Length",[385,1400,1401],{"align":374},"Up to 1,000 m (Trunk) \u002F 200 m (Spur) over shielded twisted pair",[369,1403,1404,1409],{},[385,1405,1406],{"align":374},[29,1407,1408],{},"Optical Trunk Ports",[385,1410,1411],{"align":374},"2x or 4x 100\u002F1000 Mbps SFP fiber uplinks (Multimode \u002F Singlemode)",[369,1413,1414,1419],{},[385,1415,1416],{"align":374},[29,1417,1418],{},"Supported Protocols",[385,1420,1421],{"align":374},"PROFINET, EtherNet\u002FIP, HART-IP, OPC UA, Modbus TCP",[359,1423,1425],{"label":1424},"Hazardous Zone and Electrical Ratings",[363,1426,1427,1437],{},[366,1428,1429],{},[369,1430,1431,1434],{},[372,1432,1433],{"align":374},"Standard \u002F Certification",[372,1435,1436],{"align":374},"Certified Protection Level",[380,1438,1439,1449,1459,1469,1479],{},[369,1440,1441,1446],{},[385,1442,1443],{"align":374},[29,1444,1445],{},"Switch Installation Zone",[385,1447,1448],{"align":374},"ATEX \u002F IECEx Zone 2 \u002F Class I Div 2 compliant",[369,1450,1451,1456],{},[385,1452,1453],{"align":374},[29,1454,1455],{},"Field Instrument Zone",[385,1457,1458],{"align":374},"Intrinsically Safe Ex ia \u002F Ex ic for Zones 0, 1, and 2",[369,1460,1461,1466],{},[385,1462,1463],{"align":374},[29,1464,1465],{},"Power Class Support",[385,1467,1468],{"align":374},"Power Class A, B, and C (supporting up to 500 mW Ex ia power)",[369,1470,1471,1476],{},[385,1472,1473],{"align":374},[29,1474,1475],{},"Input Operating Voltage",[385,1477,1478],{"align":374},"Redundant 24 VDC (18 to 30 VDC) terminal block inputs",[369,1480,1481,1486],{},[385,1482,1483],{"align":374},[29,1484,1485],{},"Electromagnetic Immunity",[385,1487,1488],{"align":374},"Exceeds EN 61000-6-2 heavy industrial EMC standards",[359,1490,1492],{"label":1491},"System Software and Redundancy",[363,1493,1494,1502],{},[366,1495,1496],{},[369,1497,1498,1500],{},[372,1499,444],{"align":374},[372,1501,447],{"align":374},[380,1503,1504,1514,1524,1534,1543],{},[369,1505,1506,1511],{},[385,1507,1508],{"align":374},[29,1509,1510],{},"System Firmware",[385,1512,1513],{"align":374},"Hirschmann HiOS (High Performance Operating System)",[369,1515,1516,1521],{},[385,1517,1518],{"align":374},[29,1519,1520],{},"Redundancy Protocols",[385,1522,1523],{"align":374},"HiPER Ring (recovery \u003C 20 ms), MRP, RSTP\u002FSTP, Trunking",[369,1525,1526,1531],{},[385,1527,1528],{"align":374},[29,1529,1530],{},"Time Synchronization",[385,1532,1533],{"align":374},"IEEE 1588v2 Precision Time Protocol (PTP) & TSN support",[369,1535,1536,1540],{},[385,1537,1538],{"align":374},[29,1539,476],{},[385,1541,1542],{"align":374},"IEC 62443-4-2 compliant, IEEE 802.1X, Encrypted SSH\u002FHTTPS, ACLs",[369,1544,1545,1549],{},[385,1546,1547],{"align":374},[29,1548,496],{},[385,1550,1551],{"align":374},"Hirschmann Industrial HiVision & Belden Horizon software",[349,1553],{},[41,1555,916],{"id":915},[918,1557,1558,1565],{},[921,1559,1562],{"icon":1560,"title":1561},"i-lucide-flame","Hazardous Process Plant Field Loops",[25,1563,1564],{},"Routes intrinsically safe 10BASE-T1L loops directly to pressure, flow, and temperature transmitters in Zone 0\u002F1.",[921,1566,1568],{"icon":923,"title":1567},"High-Integrity Fiber DCS Networks",[25,1569,1570],{},"Forms a redundant optical backbone bridging field instrumentation clusters back to main DCS control rooms.",[349,1572],{},[41,1574,940],{"id":939},[25,1576,1577],{},"Access official manuals, whitepapers, and product guides directly from Belden Hirschmann:",[918,1579,1580,1586],{},[921,1581,1583],{"icon":10,"title":1582,"target":12,"to":1092},"Official Belden Hirschmann Portal",[25,1584,1585],{},"Explore the full range of Hirschmann managed switches, APL field devices, and network management tools.",[921,1587,1589],{"icon":954,"title":1588,"target":12,"to":1095},"Belden Industrial Managed Switches",[25,1590,1591],{},"Download detailed datasheets, CAD drawings, and firmware updates for BOBCAT and APL field switches.",{"title":961,"searchDepth":962,"depth":962,"links":1593},[1594,1595,1596,1597],{"id":43,"depth":965,"text":44},{"id":353,"depth":965,"text":354},{"id":915,"depth":965,"text":916},{"id":939,"depth":965,"text":940},"Hardened Ethernet switches, Ethernet-APL field devices, and media converters designed for hazardous locations and high-reliability process networks.",[1600,1601,1602,1603],"PROFINET, EtherNet\u002FIP, and HART-IP Process Automation Protocols","Hirschmann Industrial HiVision and Belden Horizon Network Management Software","Standard Field Ethernet-APL Field Instruments and Transmitters","Standard 35 mm DIN Rail and Hazardous Enclosure Mounting Assemblies","Premium fiber-uplink and Ethernet-APL field switches engineered by Belden Hirschmann for high-integrity loop routing and intrinsically safe hazardous explosion-proof zones.",[1606,1610],{"name":1607,"url":1608,"type":983,"format":984,"size":1609},"Hirschmann Ethernet-APL Field Switch Datasheet","\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fdatasheet-hirschmann-apl.pdf","2.8 MB",{"name":1611,"url":1612,"type":989,"format":984,"size":1613},"Hirschmann Ethernet-APL Technology Guide","\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fmanual-hirschmann-apl.pdf","6.5 MB",[1615,1619],{"src":1616,"alt":1617,"caption":1618},"\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fgallery-1.png","Hirschmann Ethernet-APL Field Switch mounted inside an explosion-proof terminal housing","Hardened field enclosure supporting intrinsically safe APL spurs for process instrumentation",{"src":1620,"alt":1621,"caption":1622},"\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fgallery-2.png","Hirschmann BOBCAT Managed Fiber Switch front view showing Gigabit SFP uplinks","Compact DIN rail switch featuring multi-gigabit fiber uplinks and HiOS operating system",[1624,1625,1626,1627,1628,1629],"Bridges enterprise Ethernet backbones to field instruments via Ethernet-APL (10BASE-T1L) physical layer","Delivers intrinsically safe (Ex ia \u002F Ex ic) power and data over a single 2-wire shielded twisted pair up to 1,000 m","Certified for hazardous environments including ATEX\u002FIECEx Zone 2 (installation) powering instruments in Zone 0 and 1","High-integrity redundant fiber uplinks utilizing SFP optical interfaces with sub-20 ms HiPER Ring recovery","Powered by Hirschmann HiOS software featuring TSN (Time-Sensitive Networking) and IEC 62443 security","Rugged IP30\u002FIP67 cast-aluminum enclosures resistant to extreme vibration, thermal shock, and corrosive gases","\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fimage.png","2026-10-01T07:54:00Z",{"readingTime":1633},{"text":1014,"minutes":1634,"time":1635,"words":1636},2.38,142800,476,"\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch",{"title":1639,"description":1640},"Hirschmann Ethernet-APL & Fiber Industrial Switches | NodeWave","Explore Hirschmann Ethernet-APL and Fiber Industrial Switches. Designed for explosion-proof Ex Zones 0\u002F1\u002F2, 10BASE-T1L loop routing, and HiOS process redundancy.","HIR-APL-BOBCAT-EX",[1643,1647,1650,1653,1657,1660,1663,1666,1669,1672,1675],{"category":1644,"label":1645,"value":1646},"Fieldbus and Network Interfaces","Physical Layer Technology","Ethernet-APL (10BASE-T1L per IEEE 802.3cg) + 100\u002F1000 Mbps Fiber Uplinks",{"category":1644,"label":1648,"value":1649},"Field Spur Output","Up to 16x 2-wire Single-Pair Ethernet (SPE) ports with power over APL",{"category":1644,"label":1651,"value":1652},"Uplink Interfaces","2x or 4x Gigabit SFP\u002FST\u002FSC optical fiber ports (Multimode \u002F Singlemode)",{"category":1654,"label":1655,"value":1656},"Explosion Protection and Certification","Hazardous Area Certification","ATEX \u002F IECEx Zone 2 installation | Field spurs certified Ex ia (Zone 0\u002F1)",{"category":1654,"label":1658,"value":1659},"Intrinsically Safe Power","Power Class A, B, and C support for Ex ia\u002FEx ic field transmitters",{"category":1661,"label":1662,"value":1513},"Operating Software and Security","Switch Firmware",{"category":1661,"label":1664,"value":1665},"Network Redundancy","HiPER Ring, MRP (Media Redundancy Protocol), RSTP, Link Aggregation",{"category":1661,"label":1667,"value":1668},"Cybersecurity Compliance","IEC 62443-4-2 Level 2, IEEE 802.1X, RADIUS, Port Security, Encrypted Management",{"category":1052,"label":1670,"value":1671},"Operating Input Voltage","Redundant 24 VDC (18 to 30 VDC) input via terminal blocks",{"category":1052,"label":1673,"value":1674},"Dimensions and Housing","Heavy-duty IP30 metal \u002F IP67 die-cast aluminum field enclosure",{"category":1052,"label":585,"value":1059,"unit":1060},"store\u002Fnetworking\u002Fhirschmann-apl-switch",[1678,1679,1680,1681,1682,1683],"Hirschmann","Belden","Ethernet-APL","Hazardous Zone","Intrinsically Safe","10BASE-T1L",[1685,1686,1687,1688],"Chemical and Petrochemical Process Control Field Loop Communications","Explosion-Proof Hazardous Zone (Zone 0\u002F1\u002F2) Process Instrumentation Routing","Pharmaceutical Cleanroom and Distillation Plant Network Backbones","Offshore Platform and Marine Oil & Gas Infrastructure Monitoring","xn8Hivi4i77k71wRisIDix0FTmjpdPn0-M08-uBq2r4",{"id":1691,"title":1692,"_path":6,"anchors":1693,"badge":1700,"body":1701,"category":969,"categoryDescription":970,"categoryIcon":126,"compareAtPrice":6,"compatibility":3021,"currency":976,"date":977,"description":3026,"downloads":3027,"draft":991,"excerpt":6,"extension":992,"featured":991,"gallery":3036,"highlights":3045,"image":3052,"inStock":1010,"lastUpdated":3053,"meta":3054,"navigation":1010,"path":3060,"price":6,"seo":3061,"sku":3064,"specs":3065,"stem":3100,"tags":3101,"useCases":3106,"version":6,"__hash__":3111},"store\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e.md","Moxa EDS-G508E 8-Port Gigabit Managed Switch",[1694,1697],{"label":1695,"icon":10,"to":1696,"target":12},"Official Moxa EDS-G508E Product Page","https:\u002F\u002Fwww.moxa.com\u002Fen\u002Fproducts\u002Findustrial-network-infrastructure\u002Fethernet-switches\u002Flayer-2-managed-switches\u002Feds-g508e-series\u002Feds-g508e",{"label":1698,"icon":15,"to":1699,"target":12},"Moxa Industrial Ethernet Solution Portal","https:\u002F\u002Fwww.moxa.com\u002Fen\u002Fproducts\u002Findustrial-network-infrastructure\u002Fethernet-switches","Heavy EMC Shielded",{"type":19,"value":1702,"toc":3015},[1703,1711,1713,1718,1765,1890,1892,1894,2975,2977,2979,2993,2995,2997,3000],[22,1704,1705],{},[25,1706,27,1707,1710],{},[29,1708,1709],{},"Moxa EDS-G508E"," is an 8-port full Gigabit Layer 2 managed Ethernet switch engineered specifically for harsh\ncontrol room environments. Equipped with heavy electromagnetic immunity shielding, it suppresses electrical noise\ndistortion caused by high-voltage equipment, frequency drives, and heavy motors.",[41,1712,44],{"id":43},[25,1714,27,1715,1717],{},[29,1716,1709],{}," series delivers high-density Gigabit routing to keep automation loops uninterrupted. Built to\nsatisfy strict heavy-industrial EMC regulations (EN 61000-6-2\u002F6-4 and IEC 61000-4 EMS standards), the switch eliminates\npacket dropouts and signal interference in heavy industrial setups.",[110,1719,1720],{"color":112,"icon":113},[25,1721,1722,1725,1726,1764],{},[29,1723,1724],{},"Ultra-Fast Ring Recovery:"," Moxa's Turbo Ring and Turbo Chain technologies provide self-healing network link\nredundancy with a failover recovery time under ",[52,1727,1729,1746],{"className":1728},[55],[52,1730,1732],{"className":1731},[59],[61,1733,1734],{"xmlns":63},[65,1735,1736,1743],{},[68,1737,1738,1740],{},[71,1739,690],{},[75,1741,1742],{}," ms",[79,1744,1745],{"encoding":81},"50\\text{ ms}",[52,1747,1749],{"className":1748,"ariaHidden":87},[86],[52,1750,1752,1755,1758],{"className":1751},[91],[52,1753],{"className":1754,"style":803},[95],[52,1756,690],{"className":1757},[100],[52,1759,1761],{"className":1760},[100,104],[52,1762,1742],{"className":1763},[100]," across up to 250 connected switches.",[121,1766,1767,1829],{},[124,1768,1769],{"icon":126,"label":127},[129,1770,1771,1817,1823],{},[132,1772,1773,1776,1777,1816],{},[29,1774,1775],{},"Heavy-Duty EMC Noise Resistance:"," Built to withstand severe electrical noise, ESD surges up to ",[52,1778,1780,1798],{"className":1779},[55],[52,1781,1783],{"className":1782},[59],[61,1784,1785],{"xmlns":63},[65,1786,1787,1795],{},[68,1788,1789,1792],{},[71,1790,1791],{},"15",[75,1793,1794],{}," kV",[79,1796,1797],{"encoding":81},"15\\text{ kV}",[52,1799,1801],{"className":1800,"ariaHidden":87},[86],[52,1802,1804,1807,1810],{"className":1803},[91],[52,1805],{"className":1806,"style":655},[95],[52,1808,1791],{"className":1809},[100],[52,1811,1813],{"className":1812},[100,104],[52,1814,1794],{"className":1815},[100],", and\ncontinuous electromagnetic fields.",[132,1818,1819,1822],{},[29,1820,1821],{},"Industrial Protocol Integration:"," Supports EtherNet\u002FIP, PROFINET, and Modbus TCP for easy monitoring inside SCADA\nand PLC diagnostic environments.",[132,1824,1825,1828],{},[29,1826,1827],{},"IEC 62443 Cybersecurity Baseline:"," Integrates port-based security, RADIUS\u002FTACACS+ authentication, IEEE 802.1X, and\nHTTPS\u002FSSH encrypted management.",[124,1830,1831,1887],{"icon":152,"label":153},[25,1832,1833,1834,1886],{},"The switch features eight Gigabit 10\u002F100\u002F1000BaseT (X) copper RJ45 ports housed in a rugged IP30 metal casing. It\nincorporates dual redundant terminal block power inputs accepting wide ranges (",[52,1835,1837,1859],{"className":1836},[55],[52,1838,1840],{"className":1839},[59],[61,1841,1842],{"xmlns":63},[65,1843,1844,1856],{},[68,1845,1846,1849,1851,1854],{},[71,1847,1848],{},"12",[75,1850,310],{},[71,1852,1853],{},"48",[75,1855,316],{},[79,1857,1858],{"encoding":81},"12\\text{ to }48\\text{ VDC}",[52,1860,1862],{"className":1861,"ariaHidden":87},[86],[52,1863,1865,1868,1871,1877,1880],{"className":1864},[91],[52,1866],{"className":1867,"style":96},[95],[52,1869,1848],{"className":1870},[100],[52,1872,1874],{"className":1873},[100,104],[52,1875,310],{"className":1876},[100],[52,1878,1853],{"className":1879},[100],[52,1881,1883],{"className":1882},[100,104],[52,1884,316],{"className":1885},[100],") alongside\nbuilt-in alarm relay contacts to trigger physical sirens or PLC inputs upon link failure.",[25,1888,1889],{},"System backups are made simple using the USB Type-A port, which interfaces directly with the optional ABC-02-USB\nconfigurator for rapid zero-laptop field replacements.",[349,1891],{},[41,1893,354],{"id":353},[356,1895,1896,1961,2337],{},[359,1897,1899],{"label":1898},"Network Performance and Protocols",[363,1900,1901,1909],{},[366,1902,1903],{},[369,1904,1905,1907],{},[372,1906,375],{"align":374},[372,1908,378],{"align":374},[380,1910,1911,1921,1931,1941,1951],{},[369,1912,1913,1918],{},[385,1914,1915],{"align":374},[29,1916,1917],{},"Ethernet Interfaces",[385,1919,1920],{"align":374},"8x 10\u002F100\u002F1000BaseT(X) Gigabit RJ45 ports",[369,1922,1923,1928],{},[385,1924,1925],{"align":374},[29,1926,1927],{},"Switching Characteristics",[385,1929,1930],{"align":374},"MAC Table: 8K",[369,1932,1933,1938],{},[385,1934,1935],{"align":374},[29,1936,1937],{},"Redundancy Features",[385,1939,1940],{"align":374},"Turbo Ring v1\u002Fv2, Turbo Chain, RSTP\u002FSTP, MSTP, Trunking",[369,1942,1943,1948],{},[385,1944,1945],{"align":374},[29,1946,1947],{},"Fieldbus Support",[385,1949,1950],{"align":374},"Native EtherNet\u002FIP, PROFINET IO, Modbus TCP",[369,1952,1953,1958],{},[385,1954,1955],{"align":374},[29,1956,1957],{},"Management Software",[385,1959,1960],{"align":374},"Supported by MXstudio and MXview One network platforms",[359,1962,1964],{"label":1963},"EMC Immunity and Regulatory",[363,1965,1966,1976],{},[366,1967,1968],{},[369,1969,1970,1973],{},[372,1971,1972],{"align":374},"Standard \u002F Test",[372,1974,1975],{"align":374},"Certified Level",[380,1977,1978,2063,2161,2245,2327],{},[369,1979,1980,1985],{},[385,1981,1982],{"align":374},[29,1983,1984],{},"Electrostatic Discharge (ESD)",[385,1986,1987,1988,2026,2027],{"align":374},"IEC 61000-4-2: Contact: ",[52,1989,1991,2008],{"className":1990},[55],[52,1992,1994],{"className":1993},[59],[61,1995,1996],{"xmlns":63},[65,1997,1998,2005],{},[68,1999,2000,2003],{},[71,2001,2002],{},"8",[75,2004,1794],{},[79,2006,2007],{"encoding":81},"8\\text{ kV}",[52,2009,2011],{"className":2010,"ariaHidden":87},[86],[52,2012,2014,2017,2020],{"className":2013},[91],[52,2015],{"className":2016,"style":655},[95],[52,2018,2002],{"className":2019},[100],[52,2021,2023],{"className":2022},[100,104],[52,2024,1794],{"className":2025},[100],"; Air: ",[52,2028,2030,2045],{"className":2029},[55],[52,2031,2033],{"className":2032},[59],[61,2034,2035],{"xmlns":63},[65,2036,2037,2043],{},[68,2038,2039,2041],{},[71,2040,1791],{},[75,2042,1794],{},[79,2044,1797],{"encoding":81},[52,2046,2048],{"className":2047,"ariaHidden":87},[86],[52,2049,2051,2054,2057],{"className":2050},[91],[52,2052],{"className":2053,"style":655},[95],[52,2055,1791],{"className":2056},[100],[52,2058,2060],{"className":2059},[100,104],[52,2061,1794],{"className":2062},[100],[369,2064,2065,2070],{},[385,2066,2067],{"align":374},[29,2068,2069],{},"Radiated Susceptibility (RS)",[385,2071,2072,2073],{"align":374},"IEC 61000-4-3: ",[52,2074,2076,2107],{"className":2075},[55],[52,2077,2079],{"className":2078},[59],[61,2080,2081],{"xmlns":63},[65,2082,2083,2104],{},[68,2084,2085,2088,2091,2093,2096,2099,2101],{},[71,2086,2087],{},"80",[75,2089,2090],{}," MHz to ",[71,2092,1179],{},[75,2094,2095],{}," GHz",[170,2097,2098],{},":",[71,2100,1138],{},[75,2102,2103],{}," V\u002Fm",[79,2105,2106],{"encoding":81},"80\\text{ MHz to }1\\text{ GHz}: 10\\text{ V\u002Fm}",[52,2108,2110,2145],{"className":2109,"ariaHidden":87},[86],[52,2111,2113,2116,2119,2125,2128,2134,2138,2142],{"className":2112},[91],[52,2114],{"className":2115,"style":96},[95],[52,2117,2087],{"className":2118},[100],[52,2120,2122],{"className":2121},[100,104],[52,2123,2090],{"className":2124},[100],[52,2126,1179],{"className":2127},[100],[52,2129,2131],{"className":2130},[100,104],[52,2132,2095],{"className":2133},[100],[52,2135],{"className":2136,"style":2137},[640],"margin-right:0.2778em;",[52,2139,2098],{"className":2140},[2141],"mrel",[52,2143],{"className":2144,"style":2137},[640],[52,2146,2148,2152,2155],{"className":2147},[91],[52,2149],{"className":2150,"style":2151},[95],"height:1em;vertical-align:-0.25em;",[52,2153,1138],{"className":2154},[100],[52,2156,2158],{"className":2157},[100,104],[52,2159,2103],{"className":2160},[100],[369,2162,2163,2168],{},[385,2164,2165],{"align":374},[29,2166,2167],{},"Electrical Fast Transient (EFT)",[385,2169,2170,2171,2208,2209],{"align":374},"IEC 61000-4-4: Power: ",[52,2172,2174,2190],{"className":2173},[55],[52,2175,2177],{"className":2176},[59],[61,2178,2179],{"xmlns":63},[65,2180,2181,2187],{},[68,2182,2183,2185],{},[71,2184,267],{},[75,2186,1794],{},[79,2188,2189],{"encoding":81},"4\\text{ kV}",[52,2191,2193],{"className":2192,"ariaHidden":87},[86],[52,2194,2196,2199,2202],{"className":2195},[91],[52,2197],{"className":2198,"style":655},[95],[52,2200,267],{"className":2201},[100],[52,2203,2205],{"className":2204},[100,104],[52,2206,1794],{"className":2207},[100],"; Signal: ",[52,2210,2212,2227],{"className":2211},[55],[52,2213,2215],{"className":2214},[59],[61,2216,2217],{"xmlns":63},[65,2218,2219,2225],{},[68,2220,2221,2223],{},[71,2222,267],{},[75,2224,1794],{},[79,2226,2189],{"encoding":81},[52,2228,2230],{"className":2229,"ariaHidden":87},[86],[52,2231,2233,2236,2239],{"className":2232},[91],[52,2234],{"className":2235,"style":655},[95],[52,2237,267],{"className":2238},[100],[52,2240,2242],{"className":2241},[100,104],[52,2243,1794],{"className":2244},[100],[369,2246,2247,2252],{},[385,2248,2249],{"align":374},[29,2250,2251],{},"Surge Protection",[385,2253,2254,2255,2208,2291],{"align":374},"IEC 61000-4-5: Power: ",[52,2256,2258,2273],{"className":2257},[55],[52,2259,2261],{"className":2260},[59],[61,2262,2263],{"xmlns":63},[65,2264,2265,2271],{},[68,2266,2267,2269],{},[71,2268,267],{},[75,2270,1794],{},[79,2272,2189],{"encoding":81},[52,2274,2276],{"className":2275,"ariaHidden":87},[86],[52,2277,2279,2282,2285],{"className":2278},[91],[52,2280],{"className":2281,"style":655},[95],[52,2283,267],{"className":2284},[100],[52,2286,2288],{"className":2287},[100,104],[52,2289,1794],{"className":2290},[100],[52,2292,2294,2309],{"className":2293},[55],[52,2295,2297],{"className":2296},[59],[61,2298,2299],{"xmlns":63},[65,2300,2301,2307],{},[68,2302,2303,2305],{},[71,2304,267],{},[75,2306,1794],{},[79,2308,2189],{"encoding":81},[52,2310,2312],{"className":2311,"ariaHidden":87},[86],[52,2313,2315,2318,2321],{"className":2314},[91],[52,2316],{"className":2317,"style":655},[95],[52,2319,267],{"className":2320},[100],[52,2322,2324],{"className":2323},[100,104],[52,2325,1794],{"className":2326},[100],[369,2328,2329,2334],{},[385,2330,2331],{"align":374},[29,2332,2333],{},"EMC Heavy Industrial",[385,2335,2336],{"align":374},"EN 61000-6-2 \u002F EN 61000-6-4 compliant",[359,2338,2340],{"label":2339},"Electrical and Mechanical",[363,2341,2342,2350],{},[366,2343,2344],{},[369,2345,2346,2348],{},[372,2347,511],{"align":374},[372,2349,514],{"align":374},[380,2351,2352,2457,2558,2713,2888],{},[369,2353,2354,2359],{},[385,2355,2356],{"align":374},[29,2357,2358],{},"Power Input Voltage",[385,2360,2361,2456],{"align":374},[52,2362,2364,2396],{"className":2363},[55],[52,2365,2367],{"className":2366},[59],[61,2368,2369],{"xmlns":63},[65,2370,2371,2393],{},[68,2372,2373,2375,2378,2381,2383,2385,2387,2389,2391],{},[71,2374,1848],{},[75,2376,2377],{}," \u002F ",[71,2379,2380],{},"24",[75,2382,2377],{},[71,2384,1853],{},[75,2386,2377],{},[170,2388,172],{},[71,2390,1853],{},[75,2392,316],{},[79,2394,2395],{"encoding":81},"12\\text{ \u002F }24\\text{ \u002F }48\\text{ \u002F }-48\\text{ VDC}",[52,2397,2399,2441],{"className":2398,"ariaHidden":87},[86],[52,2400,2402,2405,2408,2414,2417,2423,2426,2432,2435,2438],{"className":2401},[91],[52,2403],{"className":2404,"style":2151},[95],[52,2406,1848],{"className":2407},[100],[52,2409,2411],{"className":2410},[100,104],[52,2412,2377],{"className":2413},[100],[52,2415,2380],{"className":2416},[100],[52,2418,2420],{"className":2419},[100,104],[52,2421,2377],{"className":2422},[100],[52,2424,1853],{"className":2425},[100],[52,2427,2429],{"className":2428},[100,104],[52,2430,2377],{"className":2431},[100],[52,2433],{"className":2434,"style":641},[640],[52,2436,172],{"className":2437},[645],[52,2439],{"className":2440,"style":641},[640],[52,2442,2444,2447,2450],{"className":2443},[91],[52,2445],{"className":2446,"style":96},[95],[52,2448,1853],{"className":2449},[100],[52,2451,2453],{"className":2452},[100,104],[52,2454,316],{"className":2455},[100]," redundant dual inputs",[369,2458,2459,2464],{},[385,2460,2461],{"align":374},[29,2462,2463],{},"Current Consumption",[385,2465,2466,813,2518,2557],{"align":374},[52,2467,2469,2491],{"className":2468},[55],[52,2470,2472],{"className":2471},[59],[61,2473,2474],{"xmlns":63},[65,2475,2476,2488],{},[68,2477,2478,2481,2484,2486],{},[71,2479,2480],{},"0.28",[75,2482,2483],{}," A @ ",[71,2485,2380],{},[75,2487,316],{},[79,2489,2490],{"encoding":81},"0.28\\text{ A @ }24\\text{ VDC}",[52,2492,2494],{"className":2493,"ariaHidden":87},[86],[52,2495,2497,2500,2503,2509,2512],{"className":2496},[91],[52,2498],{"className":2499,"style":655},[95],[52,2501,2480],{"className":2502},[100],[52,2504,2506],{"className":2505},[100,104],[52,2507,2483],{"className":2508},[100],[52,2510,2380],{"className":2511},[100],[52,2513,2515],{"className":2514},[100,104],[52,2516,316],{"className":2517},[100],[52,2519,2521,2539],{"className":2520},[55],[52,2522,2524],{"className":2523},[59],[61,2525,2526],{"xmlns":63},[65,2527,2528,2536],{},[68,2529,2530,2533],{},[71,2531,2532],{},"0.37",[75,2534,2535],{}," A",[79,2537,2538],{"encoding":81},"0.37\\text{ A}",[52,2540,2542],{"className":2541,"ariaHidden":87},[86],[52,2543,2545,2548,2551],{"className":2544},[91],[52,2546],{"className":2547,"style":96},[95],[52,2549,2532],{"className":2550},[100],[52,2552,2554],{"className":2553},[100,104],[52,2555,2535],{"className":2556},[100]," max)",[369,2559,2560,2565],{},[385,2561,2562],{"align":374},[29,2563,2564],{},"Standard Operating Temp",[385,2566,2567,813,2639,2712],{"align":374},[52,2568,2570,2594],{"className":2569},[55],[52,2571,2573],{"className":2572},[59],[61,2574,2575],{"xmlns":63},[65,2576,2577,2591],{},[68,2578,2579,2581,2583,2585,2587,2589],{},[170,2580,172],{},[71,2582,1138],{},[75,2584,606],{},[170,2586,219],{},[71,2588,313],{},[75,2590,178],{},[79,2592,2593],{"encoding":81},"-10\\text{ °C to }+60\\text{ °C}",[52,2595,2597,2624],{"className":2596,"ariaHidden":87},[86],[52,2598,2600,2603,2606,2609,2615,2618,2621],{"className":2599},[91],[52,2601],{"className":2602,"style":191},[95],[52,2604,172],{"className":2605},[100],[52,2607,1138],{"className":2608},[100],[52,2610,2612],{"className":2611},[100,104],[52,2613,606],{"className":2614},[100],[52,2616],{"className":2617,"style":641},[640],[52,2619,219],{"className":2620},[645],[52,2622],{"className":2623,"style":641},[640],[52,2625,2627,2630,2633],{"className":2626},[91],[52,2628],{"className":2629,"style":655},[95],[52,2631,313],{"className":2632},[100],[52,2634,2636],{"className":2635},[100,104],[52,2637,178],{"className":2638},[100],[52,2640,2642,2667],{"className":2641},[55],[52,2643,2645],{"className":2644},[59],[61,2646,2647],{"xmlns":63},[65,2648,2649,2664],{},[68,2650,2651,2653,2655,2657,2659,2662],{},[170,2652,172],{},[71,2654,175],{},[75,2656,606],{},[170,2658,219],{},[71,2660,2661],{},"75",[75,2663,178],{},[79,2665,2666],{"encoding":81},"-40\\text{ °C to }+75\\text{ °C}",[52,2668,2670,2697],{"className":2669,"ariaHidden":87},[86],[52,2671,2673,2676,2679,2682,2688,2691,2694],{"className":2672},[91],[52,2674],{"className":2675,"style":191},[95],[52,2677,172],{"className":2678},[100],[52,2680,175],{"className":2681},[100],[52,2683,2685],{"className":2684},[100,104],[52,2686,606],{"className":2687},[100],[52,2689],{"className":2690,"style":641},[640],[52,2692,219],{"className":2693},[645],[52,2695],{"className":2696,"style":641},[640],[52,2698,2700,2703,2706],{"className":2699},[91],[52,2701],{"className":2702,"style":655},[95],[52,2704,2661],{"className":2705},[100],[52,2707,2709],{"className":2708},[100,104],[52,2710,178],{"className":2711},[100]," for -T model)",[369,2714,2715,2720],{},[385,2716,2717],{"align":374},[29,2718,2719],{},"Enclosure Dimensions",[385,2721,2722,813,2805,900],{"align":374},[52,2723,2725,2751],{"className":2724},[55],[52,2726,2728],{"className":2727},[59],[61,2729,2730],{"xmlns":63},[65,2731,2732,2748],{},[68,2733,2734,2737,2739,2741,2743,2746],{},[71,2735,2736],{},"79.2",[170,2738,742],{},[71,2740,750],{},[170,2742,742],{},[71,2744,2745],{},"137",[75,2747,753],{},[79,2749,2750],{"encoding":81},"79.2\\times 135\\times 137\\text{ mm}",[52,2752,2754,2772,2790],{"className":2753,"ariaHidden":87},[86],[52,2755,2757,2760,2763,2766,2769],{"className":2756},[91],[52,2758],{"className":2759,"style":766},[95],[52,2761,2736],{"className":2762},[100],[52,2764],{"className":2765,"style":641},[640],[52,2767,742],{"className":2768},[645],[52,2770],{"className":2771,"style":641},[640],[52,2773,2775,2778,2781,2784,2787],{"className":2774},[91],[52,2776],{"className":2777,"style":766},[95],[52,2779,750],{"className":2780},[100],[52,2782],{"className":2783,"style":641},[640],[52,2785,742],{"className":2786},[645],[52,2788],{"className":2789,"style":641},[640],[52,2791,2793,2796,2799],{"className":2792},[91],[52,2794],{"className":2795,"style":803},[95],[52,2797,2745],{"className":2798},[100],[52,2800,2802],{"className":2801},[100,104],[52,2803,753],{"className":2804},[100],[52,2806,2808,2834],{"className":2807},[55],[52,2809,2811],{"className":2810},[59],[61,2812,2813],{"xmlns":63},[65,2814,2815,2831],{},[68,2816,2817,2820,2822,2824,2826,2829],{},[71,2818,2819],{},"3.1",[170,2821,742],{},[71,2823,838],{},[170,2825,742],{},[71,2827,2828],{},"5.4",[75,2830,841],{},[79,2832,2833],{"encoding":81},"3.1\\times 5.3\\times 5.4\\text{ in}",[52,2835,2837,2855,2873],{"className":2836,"ariaHidden":87},[86],[52,2838,2840,2843,2846,2849,2852],{"className":2839},[91],[52,2841],{"className":2842,"style":766},[95],[52,2844,2819],{"className":2845},[100],[52,2847],{"className":2848,"style":641},[640],[52,2850,742],{"className":2851},[645],[52,2853],{"className":2854,"style":641},[640],[52,2856,2858,2861,2864,2867,2870],{"className":2857},[91],[52,2859],{"className":2860,"style":766},[95],[52,2862,838],{"className":2863},[100],[52,2865],{"className":2866,"style":641},[640],[52,2868,742],{"className":2869},[645],[52,2871],{"className":2872,"style":641},[640],[52,2874,2876,2879,2882],{"className":2875},[91],[52,2877],{"className":2878,"style":890},[95],[52,2880,2828],{"className":2881},[100],[52,2883,2885],{"className":2884},[100,104],[52,2886,841],{"className":2887},[100],[369,2889,2890,2895],{},[385,2891,2892],{"align":374},[29,2893,2894],{},"Weight and Ingress Rating",[385,2896,2897,813,2936,900],{"align":374},[52,2898,2900,2918],{"className":2899},[55],[52,2901,2903],{"className":2902},[59],[61,2904,2905],{"xmlns":63},[65,2906,2907,2915],{},[68,2908,2909,2912],{},[71,2910,2911],{},"1440",[75,2913,2914],{}," g",[79,2916,2917],{"encoding":81},"1440\\text{ g}",[52,2919,2921],{"className":2920,"ariaHidden":87},[86],[52,2922,2924,2927,2930],{"className":2923},[91],[52,2925],{"className":2926,"style":1201},[95],[52,2928,2911],{"className":2929},[100],[52,2931,2933],{"className":2932},[100,104],[52,2934,2914],{"className":2935},[100],[52,2937,2939,2957],{"className":2938},[55],[52,2940,2942],{"className":2941},[59],[61,2943,2944],{"xmlns":63},[65,2945,2946,2954],{},[68,2947,2948,2951],{},[71,2949,2950],{},"3.18",[75,2952,2953],{}," lb",[79,2955,2956],{"encoding":81},"3.18\\text{ lb}",[52,2958,2960],{"className":2959,"ariaHidden":87},[86],[52,2961,2963,2966,2969],{"className":2962},[91],[52,2964],{"className":2965,"style":655},[95],[52,2967,2950],{"className":2968},[100],[52,2970,2972],{"className":2971},[100,104],[52,2973,2953],{"className":2974},[100],[349,2976],{},[41,2978,916],{"id":915},[918,2980,2981,2987],{},[921,2982,2984],{"icon":923,"title":2983},"Factory Control Room Backbones",[25,2985,2986],{},"Protects high-volume DCS automation signals against electromagnetic field interference in dense motor cabinets.",[921,2988,2990],{"icon":930,"title":2989},"Substation and Power Grid Distribution",[25,2991,2992],{},"Delivers high ESD and surge protection for digital power substation telemetry and real-time monitoring.",[349,2994],{},[41,2996,940],{"id":939},[25,2998,2999],{},"Access official hardware manuals, datasheets, and firmware tools from Moxa:",[918,3001,3002,3008],{},[921,3003,3005],{"icon":10,"title":3004,"target":12,"to":1696},"Official Moxa EDS-G508E Portal",[25,3006,3007],{},"Download firmware updates, MIB files, and official CAD drawings directly from Moxa.",[921,3009,3012],{"icon":954,"title":3010,"target":12,"to":3011},"Moxa EDS-G508E Series Datasheet","https:\u002F\u002Fwww.moxa.com\u002Fgetmedia\u002F32c7a490-8f76-4bea-bba8-53f5d881bbdf\u002Fmoxa-eds-g508e-series-datasheet-v1.3.pdf",[25,3013,3014],{},"Review complete EMC immunity test reports, ordering options, and accessory compatibility tables.",{"title":961,"searchDepth":962,"depth":962,"links":3016},[3017,3018,3019,3020],{"id":43,"depth":965,"text":44},{"id":353,"depth":965,"text":354},{"id":915,"depth":965,"text":916},{"id":939,"depth":965,"text":940},[3022,3023,3024,3025],"Moxa MXstudio Network Management Suite and MXview One Platform","Moxa ABC-02-USB Automatic Backup Configurator","Standard EtherNet\u002FIP, PROFINET, and Modbus TCP Controllers","Standard 35 mm DIN Rail and Wall Mounting Systems","Rugged 8-port full Gigabit Layer 2 managed Ethernet switch featuring heavy electromagnetic noise immunity and millisecond-level network redundancy for industrial control rooms.",[3028,3032],{"name":3029,"url":3030,"type":983,"format":984,"size":3031},"Moxa EDS-G508E Series Official Datasheet","\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fdatasheet-moxa-eds-g508e.pdf","1.4 MB",{"name":3033,"url":3034,"type":989,"format":984,"size":3035},"Moxa EDS-G508E Hardware Installation Manual","\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fmanual-moxa-eds-g508e.pdf","4.8 MB",[3037,3041],{"src":3038,"alt":3039,"caption":3040},"\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fgallery-1.png","Moxa EDS-G508E full front panel layout with status LEDs and 8 Gigabit RJ45 ports","Heavy-duty IP30 metal enclosure with 8 Gigabit RJ45 ports, USB console, and system status indicators",{"src":3042,"alt":3043,"caption":3044},"\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fgallery-2.png","Moxa EDS-G508E mounted on a DIN rail inside an industrial control enclosure","Compact DIN rail footprint featuring redundant terminal block power inputs and relay contact alarms",[3046,3047,3048,3049,3050,3051],"8 full Gigabit 10\u002F100\u002F1000BaseT(X) Ethernet ports for high-bandwidth backbone automation","Heavy electromagnetic noise immunity compliant with EN 61000-6-2 and IEC 61000-4 EMS standards","Redundant network topologies with Turbo Ring and Turbo Chain (recovery time under 50 ms at 250 switches)","Cybersecurity features based on IEC 62443 standards with RADIUS, TACACS+, MAC ACL, and HTTPS\u002FSSH support","Seamless integration into industrial automation networks via native EtherNet\u002FIP, PROFINET, and Modbus TCP","Flexible dual power inputs (12\u002F24\u002F48\u002F-48 VDC) with reverse polarity and overload current protection","\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fimage.png","2026-10-01T07:41:00Z",{"readingTime":3055},{"text":3056,"minutes":3057,"time":3058,"words":3059},"2 min read",1.9,114000,380,"\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e",{"title":3062,"description":3063},"Moxa EDS-G508E 8-Port Gigabit Managed Switch | NodeWave","Explore the Moxa EDS-G508E Managed Switch. Featuring 8 full Gigabit ports, heavy EMC shielding, Turbo Ring redundancy, and IEC 62443 cyber protection.","MOXA-EDS-G508E",[3066,3070,3073,3076,3079,3081,3084,3088,3091,3093,3096,3098],{"category":3067,"label":3068,"value":3069},"Port and Interface Configuration","Gigabit Ethernet Ports","8x 10\u002F100\u002F1000BaseT(X) RJ45 auto-negotiation ports",{"category":3067,"label":3071,"value":3072},"Console and Storage Ports","1x USB-serial console (Type-B), 1x USB Type-A configuration port",{"category":3067,"label":3074,"value":3075},"Alarm and Digital Input","1x Relay output (1 A @ 24 VDC), 1x Digital Input (+13 to +30 V for State 1)",{"category":3077,"label":1520,"value":3078},"Software and Network Security","Turbo Ring v1\u002Fv2, Turbo Chain, RSTP\u002FSTP, MSTP, Link Aggregation",{"category":3077,"label":456,"value":3080},"EtherNet\u002FIP, PROFINET IO Device, Modbus TCP",{"category":3077,"label":3082,"value":3083},"Security Features","IEEE 802.1X, RADIUS, TACACS+, MAC ACL, HTTPS, SSH, SNMPv3, Sticky MAC",{"category":3085,"label":3086,"value":3087},"EMC and Heavy Industrial Shielding","EMI Compliance","CISPR 32, FCC Part 15B Class A",{"category":3085,"label":3089,"value":3090},"EMS Immunity Standards","IEC 61000-4-2 (ESD 15kV), IEC 61000-4-3 (RS 10V\u002Fm), IEC 61000-4-4 (EFT 4kV), IEC 61000-4-5 (Surge 4kV)",{"category":1052,"label":1053,"value":3092},"12 \u002F 24 \u002F 48 \u002F -48 VDC redundant dual inputs (Operating voltage 9.6 to 60 VDC)",{"category":1052,"label":3094,"value":3095},"Power Consumption","0.28 A @ 24 VDC (0.37 A max)",{"category":1052,"label":1056,"value":3097},"79.2 x 135 x 137 mm (3.1 x 5.3 x 5.4 in) | 1440 g (3.18 lb)",{"category":1052,"label":585,"value":3099,"unit":1060},"-10 to +60","store\u002Fnetworking\u002Fmoxa-eds-g508e",[3102,3103,1065,1066,3104,3105],"Moxa","EDS-G508E","Industrial EMC Shielding","Turbo Ring",[3107,3108,3109,3110],"Factory Control Room Network Signal Isolation and High-EMC Environments","Power Substation Control and Distributed Control Systems (DCS)","Intelligent Transportation Systems (ITS) and Real-Time Video Surveillance Backbone","Water Treatment Plant High-Availability Ring Networks","tyehtD8VL6MfryrpwML8KhRCQibCkSazxt9A0Pm1vcg",1791086650522]