[{"data":1,"prerenderedAt":3108},["ShallowReactive",2],{"store-product-networking\u002Fmoxa-eds-g508e":3,"store-surround-moxa-eds-g508e":1542,"store-related-MOXA-EDS-G508E":1553},{"id":4,"title":5,"_path":6,"anchors":7,"badge":17,"body":18,"category":1432,"categoryDescription":1433,"categoryIcon":118,"compareAtPrice":6,"compatibility":1434,"currency":1439,"date":1440,"description":1441,"downloads":1442,"draft":1454,"excerpt":6,"extension":1455,"featured":1454,"gallery":1456,"highlights":1465,"image":1472,"inStock":1473,"lastUpdated":1474,"meta":1475,"navigation":1473,"path":1481,"price":6,"seo":1482,"sku":1485,"specs":1486,"stem":1528,"tags":1529,"useCases":1536,"version":6,"__hash__":1541},"store\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e.md","Moxa EDS-G508E 8-Port Gigabit Managed Switch",null,[8,13],{"label":9,"icon":10,"to":11,"target":12},"Official Moxa EDS-G508E Product Page","i-lucide-external-link","https:\u002F\u002Fwww.moxa.com\u002Fen\u002Fproducts\u002Findustrial-network-infrastructure\u002Fethernet-switches\u002Flayer-2-managed-switches\u002Feds-g508e-series\u002Feds-g508e","_blank",{"label":14,"icon":15,"to":16,"target":12},"Moxa Industrial Ethernet Solution Portal","i-lucide-book-open","https:\u002F\u002Fwww.moxa.com\u002Fen\u002Fproducts\u002Findustrial-network-infrastructure\u002Fethernet-switches","Heavy EMC Shielded",{"type":19,"value":20,"toc":1423},"minimark",[21,33,38,43,112,249,252,256,1374,1376,1380,1398,1400,1404,1407],[22,23,24],"note",{},[25,26,27,28,32],"p",{},"The ",[29,30,31],"strong",{},"Moxa EDS-G508E"," is an 8-port full Gigabit Layer 2 managed Ethernet switch engineered specifically for harsh\ncontrol room environments. Equipped with heavy electromagnetic immunity shielding, it suppresses electrical noise\ndistortion caused by high-voltage equipment, frequency drives, and heavy motors.",[34,35,37],"h2",{"id":36},"executive-summary-and-core-capabilities","Executive Summary and Core Capabilities",[25,39,27,40,42],{},[29,41,31],{}," series delivers high-density Gigabit routing to keep automation loops uninterrupted. Built to\nsatisfy strict heavy-industrial EMC regulations (EN 61000-6-2\u002F6-4 and IEC 61000-4 EMS standards), the switch eliminates\npacket dropouts and signal interference in heavy industrial setups.",[44,45,48],"callout",{"color":46,"icon":47},"green","i-lucide-shield-check",[25,49,50,53,54,111],{},[29,51,52],{},"Ultra-Fast Ring Recovery:"," Moxa's Turbo Ring and Turbo Chain technologies provide self-healing network link\nredundancy with a failover recovery time under ",[55,56,59,86],"span",{"className":57},[58],"katex",[55,60,63],{"className":61},[62],"katex-mathml",[64,65,67],"math",{"xmlns":66},"http:\u002F\u002Fwww.w3.org\u002F1998\u002FMath\u002FMathML",[68,69,70,81],"semantics",{},[71,72,73,77],"mrow",{},[74,75,76],"mn",{},"50",[78,79,80],"mtext",{}," ms",[82,83,85],"annotation",{"encoding":84},"application\u002Fx-tex","50\\text{ ms}",[55,87,91],{"className":88,"ariaHidden":90},[89],"katex-html","true",[55,92,95,100,104],{"className":93},[94],"base",[55,96],{"className":97,"style":99},[98],"strut","height:0.6444em;",[55,101,76],{"className":102},[103],"mord",[55,105,108],{"className":106},[103,107],"text",[55,109,80],{"className":110},[103]," across up to 250 connected switches.",[113,114,115,183],"accordion",{},[116,117,120],"accordion-item",{"icon":118,"label":119},"i-lucide-network","Operational Overview",[121,122,123,171,177],"ul",{},[124,125,126,129,130,170],"li",{},[29,127,128],{},"Heavy-Duty EMC Noise Resistance:"," Built to withstand severe electrical noise, ESD surges up to ",[55,131,133,151],{"className":132},[58],[55,134,136],{"className":135},[62],[64,137,138],{"xmlns":66},[68,139,140,148],{},[71,141,142,145],{},[74,143,144],{},"15",[78,146,147],{}," kV",[82,149,150],{"encoding":84},"15\\text{ kV}",[55,152,154],{"className":153,"ariaHidden":90},[89],[55,155,157,161,164],{"className":156},[94],[55,158],{"className":159,"style":160},[98],"height:0.6944em;",[55,162,144],{"className":163},[103],[55,165,167],{"className":166},[103,107],[55,168,147],{"className":169},[103],", and\ncontinuous electromagnetic fields.",[124,172,173,176],{},[29,174,175],{},"Industrial Protocol Integration:"," Supports EtherNet\u002FIP, PROFINET, and Modbus TCP for easy monitoring inside SCADA\nand PLC diagnostic environments.",[124,178,179,182],{},[29,180,181],{},"IEC 62443 Cybersecurity Baseline:"," Integrates port-based security, RADIUS\u002FTACACS+ authentication, IEEE 802.1X, and\nHTTPS\u002FSSH encrypted management.",[116,184,187,246],{"icon":185,"label":186},"i-lucide-cpu","Hardware Architecture Deep-Dive",[25,188,189,190,245],{},"The switch features eight Gigabit 10\u002F100\u002F1000BaseT (X) copper RJ45 ports housed in a rugged IP30 metal casing. It\nincorporates dual redundant terminal block power inputs accepting wide ranges (",[55,191,193,217],{"className":192},[58],[55,194,196],{"className":195},[62],[64,197,198],{"xmlns":66},[68,199,200,214],{},[71,201,202,205,208,211],{},[74,203,204],{},"12",[78,206,207],{}," to ",[74,209,210],{},"48",[78,212,213],{}," VDC",[82,215,216],{"encoding":84},"12\\text{ to }48\\text{ VDC}",[55,218,220],{"className":219,"ariaHidden":90},[89],[55,221,223,227,230,236,239],{"className":222},[94],[55,224],{"className":225,"style":226},[98],"height:0.6833em;",[55,228,204],{"className":229},[103],[55,231,233],{"className":232},[103,107],[55,234,207],{"className":235},[103],[55,237,210],{"className":238},[103],[55,240,242],{"className":241},[103,107],[55,243,213],{"className":244},[103],") alongside\nbuilt-in alarm relay contacts to trigger physical sirens or PLC inputs upon link failure.",[25,247,248],{},"System backups are made simple using the USB Type-A port, which interfaces directly with the optional ABC-02-USB\nconfigurator for rapid zero-laptop field replacements.",[250,251],"hr",{},[34,253,255],{"id":254},"technical-specifications-matrix","Technical Specifications Matrix",[257,258,259,334,715],"tabs",{},[260,261,263],"tabs-item",{"label":262},"Network Performance and Protocols",[264,265,266,280],"table",{},[267,268,269],"thead",{},[270,271,272,277],"tr",{},[273,274,276],"th",{"align":275},"left","Parameter",[273,278,279],{"align":275},"Specification Details",[281,282,283,294,304,314,324],"tbody",{},[270,284,285,291],{},[286,287,288],"td",{"align":275},[29,289,290],{},"Ethernet Interfaces",[286,292,293],{"align":275},"8x 10\u002F100\u002F1000BaseT(X) Gigabit RJ45 ports",[270,295,296,301],{},[286,297,298],{"align":275},[29,299,300],{},"Switching Characteristics",[286,302,303],{"align":275},"MAC Table: 8K",[270,305,306,311],{},[286,307,308],{"align":275},[29,309,310],{},"Redundancy Features",[286,312,313],{"align":275},"Turbo Ring v1\u002Fv2, Turbo Chain, RSTP\u002FSTP, MSTP, Trunking",[270,315,316,321],{},[286,317,318],{"align":275},[29,319,320],{},"Fieldbus Support",[286,322,323],{"align":275},"Native EtherNet\u002FIP, PROFINET IO, Modbus TCP",[270,325,326,331],{},[286,327,328],{"align":275},[29,329,330],{},"Management Software",[286,332,333],{"align":275},"Supported by MXstudio and MXview One network platforms",[260,335,337],{"label":336},"EMC Immunity and Regulatory",[264,338,339,349],{},[267,340,341],{},[270,342,343,346],{},[273,344,345],{"align":275},"Standard \u002F Test",[273,347,348],{"align":275},"Certified Level",[281,350,351,436,538,623,705],{},[270,352,353,358],{},[286,354,355],{"align":275},[29,356,357],{},"Electrostatic Discharge (ESD)",[286,359,360,361,399,400],{"align":275},"IEC 61000-4-2: Contact: ",[55,362,364,381],{"className":363},[58],[55,365,367],{"className":366},[62],[64,368,369],{"xmlns":66},[68,370,371,378],{},[71,372,373,376],{},[74,374,375],{},"8",[78,377,147],{},[82,379,380],{"encoding":84},"8\\text{ kV}",[55,382,384],{"className":383,"ariaHidden":90},[89],[55,385,387,390,393],{"className":386},[94],[55,388],{"className":389,"style":160},[98],[55,391,375],{"className":392},[103],[55,394,396],{"className":395},[103,107],[55,397,147],{"className":398},[103],"; Air: ",[55,401,403,418],{"className":402},[58],[55,404,406],{"className":405},[62],[64,407,408],{"xmlns":66},[68,409,410,416],{},[71,411,412,414],{},[74,413,144],{},[78,415,147],{},[82,417,150],{"encoding":84},[55,419,421],{"className":420,"ariaHidden":90},[89],[55,422,424,427,430],{"className":423},[94],[55,425],{"className":426,"style":160},[98],[55,428,144],{"className":429},[103],[55,431,433],{"className":432},[103,107],[55,434,147],{"className":435},[103],[270,437,438,443],{},[286,439,440],{"align":275},[29,441,442],{},"Radiated Susceptibility (RS)",[286,444,445,446],{"align":275},"IEC 61000-4-3: ",[55,447,449,483],{"className":448},[58],[55,450,452],{"className":451},[62],[64,453,454],{"xmlns":66},[68,455,456,480],{},[71,457,458,461,464,467,470,474,477],{},[74,459,460],{},"80",[78,462,463],{}," MHz to ",[74,465,466],{},"1",[78,468,469],{}," GHz",[471,472,473],"mo",{},":",[74,475,476],{},"10",[78,478,479],{}," V\u002Fm",[82,481,482],{"encoding":84},"80\\text{ MHz to }1\\text{ GHz}: 10\\text{ V\u002Fm}",[55,484,486,522],{"className":485,"ariaHidden":90},[89],[55,487,489,492,495,501,504,510,515,519],{"className":488},[94],[55,490],{"className":491,"style":226},[98],[55,493,460],{"className":494},[103],[55,496,498],{"className":497},[103,107],[55,499,463],{"className":500},[103],[55,502,466],{"className":503},[103],[55,505,507],{"className":506},[103,107],[55,508,469],{"className":509},[103],[55,511],{"className":512,"style":514},[513],"mspace","margin-right:0.2778em;",[55,516,473],{"className":517},[518],"mrel",[55,520],{"className":521,"style":514},[513],[55,523,525,529,532],{"className":524},[94],[55,526],{"className":527,"style":528},[98],"height:1em;vertical-align:-0.25em;",[55,530,476],{"className":531},[103],[55,533,535],{"className":534},[103,107],[55,536,479],{"className":537},[103],[270,539,540,545],{},[286,541,542],{"align":275},[29,543,544],{},"Electrical Fast Transient (EFT)",[286,546,547,548,586,587],{"align":275},"IEC 61000-4-4: Power: ",[55,549,551,568],{"className":550},[58],[55,552,554],{"className":553},[62],[64,555,556],{"xmlns":66},[68,557,558,565],{},[71,559,560,563],{},[74,561,562],{},"4",[78,564,147],{},[82,566,567],{"encoding":84},"4\\text{ kV}",[55,569,571],{"className":570,"ariaHidden":90},[89],[55,572,574,577,580],{"className":573},[94],[55,575],{"className":576,"style":160},[98],[55,578,562],{"className":579},[103],[55,581,583],{"className":582},[103,107],[55,584,147],{"className":585},[103],"; Signal: ",[55,588,590,605],{"className":589},[58],[55,591,593],{"className":592},[62],[64,594,595],{"xmlns":66},[68,596,597,603],{},[71,598,599,601],{},[74,600,562],{},[78,602,147],{},[82,604,567],{"encoding":84},[55,606,608],{"className":607,"ariaHidden":90},[89],[55,609,611,614,617],{"className":610},[94],[55,612],{"className":613,"style":160},[98],[55,615,562],{"className":616},[103],[55,618,620],{"className":619},[103,107],[55,621,147],{"className":622},[103],[270,624,625,630],{},[286,626,627],{"align":275},[29,628,629],{},"Surge Protection",[286,631,632,633,586,669],{"align":275},"IEC 61000-4-5: Power: ",[55,634,636,651],{"className":635},[58],[55,637,639],{"className":638},[62],[64,640,641],{"xmlns":66},[68,642,643,649],{},[71,644,645,647],{},[74,646,562],{},[78,648,147],{},[82,650,567],{"encoding":84},[55,652,654],{"className":653,"ariaHidden":90},[89],[55,655,657,660,663],{"className":656},[94],[55,658],{"className":659,"style":160},[98],[55,661,562],{"className":662},[103],[55,664,666],{"className":665},[103,107],[55,667,147],{"className":668},[103],[55,670,672,687],{"className":671},[58],[55,673,675],{"className":674},[62],[64,676,677],{"xmlns":66},[68,678,679,685],{},[71,680,681,683],{},[74,682,562],{},[78,684,147],{},[82,686,567],{"encoding":84},[55,688,690],{"className":689,"ariaHidden":90},[89],[55,691,693,696,699],{"className":692},[94],[55,694],{"className":695,"style":160},[98],[55,697,562],{"className":698},[103],[55,700,702],{"className":701},[103,107],[55,703,147],{"className":704},[103],[270,706,707,712],{},[286,708,709],{"align":275},[29,710,711],{},"EMC Heavy Industrial",[286,713,714],{"align":275},"EN 61000-6-2 \u002F EN 61000-6-4 compliant",[260,716,718],{"label":717},"Electrical and Mechanical",[264,719,720,730],{},[267,721,722],{},[270,723,724,727],{},[273,725,726],{"align":275},"Metric",[273,728,729],{"align":275},"Rating Standard",[281,731,732,840,942,1103,1286],{},[270,733,734,739],{},[286,735,736],{"align":275},[29,737,738],{},"Power Input Voltage",[286,740,741,839],{"align":275},[55,742,744,777],{"className":743},[58],[55,745,747],{"className":746},[62],[64,748,749],{"xmlns":66},[68,750,751,774],{},[71,752,753,755,758,761,763,765,767,770,772],{},[74,754,204],{},[78,756,757],{}," \u002F ",[74,759,760],{},"24",[78,762,757],{},[74,764,210],{},[78,766,757],{},[471,768,769],{},"−",[74,771,210],{},[78,773,213],{},[82,775,776],{"encoding":84},"12\\text{ \u002F }24\\text{ \u002F }48\\text{ \u002F }-48\\text{ VDC}",[55,778,780,824],{"className":779,"ariaHidden":90},[89],[55,781,783,786,789,795,798,804,807,813,817,821],{"className":782},[94],[55,784],{"className":785,"style":528},[98],[55,787,204],{"className":788},[103],[55,790,792],{"className":791},[103,107],[55,793,757],{"className":794},[103],[55,796,760],{"className":797},[103],[55,799,801],{"className":800},[103,107],[55,802,757],{"className":803},[103],[55,805,210],{"className":806},[103],[55,808,810],{"className":809},[103,107],[55,811,757],{"className":812},[103],[55,814],{"className":815,"style":816},[513],"margin-right:0.2222em;",[55,818,769],{"className":819},[820],"mbin",[55,822],{"className":823,"style":816},[513],[55,825,827,830,833],{"className":826},[94],[55,828],{"className":829,"style":226},[98],[55,831,210],{"className":832},[103],[55,834,836],{"className":835},[103,107],[55,837,213],{"className":838},[103]," redundant dual inputs",[270,841,842,847],{},[286,843,844],{"align":275},[29,845,846],{},"Current Consumption",[286,848,849,901,902,941],{"align":275},[55,850,852,874],{"className":851},[58],[55,853,855],{"className":854},[62],[64,856,857],{"xmlns":66},[68,858,859,871],{},[71,860,861,864,867,869],{},[74,862,863],{},"0.28",[78,865,866],{}," A @ ",[74,868,760],{},[78,870,213],{},[82,872,873],{"encoding":84},"0.28\\text{ A @ }24\\text{ VDC}",[55,875,877],{"className":876,"ariaHidden":90},[89],[55,878,880,883,886,892,895],{"className":879},[94],[55,881],{"className":882,"style":160},[98],[55,884,863],{"className":885},[103],[55,887,889],{"className":888},[103,107],[55,890,866],{"className":891},[103],[55,893,760],{"className":894},[103],[55,896,898],{"className":897},[103,107],[55,899,213],{"className":900},[103]," (",[55,903,905,923],{"className":904},[58],[55,906,908],{"className":907},[62],[64,909,910],{"xmlns":66},[68,911,912,920],{},[71,913,914,917],{},[74,915,916],{},"0.37",[78,918,919],{}," A",[82,921,922],{"encoding":84},"0.37\\text{ A}",[55,924,926],{"className":925,"ariaHidden":90},[89],[55,927,929,932,935],{"className":928},[94],[55,930],{"className":931,"style":226},[98],[55,933,916],{"className":934},[103],[55,936,938],{"className":937},[103,107],[55,939,919],{"className":940},[103]," max)",[270,943,944,949],{},[286,945,946],{"align":275},[29,947,948],{},"Standard Operating Temp",[286,950,951,901,1028,1102],{"align":275},[55,952,954,982],{"className":953},[58],[55,955,957],{"className":956},[62],[64,958,959],{"xmlns":66},[68,960,961,979],{},[71,962,963,965,967,970,973,976],{},[471,964,769],{},[74,966,476],{},[78,968,969],{}," °C to ",[471,971,972],{},"+",[74,974,975],{},"60",[78,977,978],{}," °C",[82,980,981],{"encoding":84},"-10\\text{ °C to }+60\\text{ °C}",[55,983,985,1013],{"className":984,"ariaHidden":90},[89],[55,986,988,992,995,998,1004,1007,1010],{"className":987},[94],[55,989],{"className":990,"style":991},[98],"height:0.7778em;vertical-align:-0.0833em;",[55,993,769],{"className":994},[103],[55,996,476],{"className":997},[103],[55,999,1001],{"className":1000},[103,107],[55,1002,969],{"className":1003},[103],[55,1005],{"className":1006,"style":816},[513],[55,1008,972],{"className":1009},[820],[55,1011],{"className":1012,"style":816},[513],[55,1014,1016,1019,1022],{"className":1015},[94],[55,1017],{"className":1018,"style":160},[98],[55,1020,975],{"className":1021},[103],[55,1023,1025],{"className":1024},[103,107],[55,1026,978],{"className":1027},[103],[55,1029,1031,1057],{"className":1030},[58],[55,1032,1034],{"className":1033},[62],[64,1035,1036],{"xmlns":66},[68,1037,1038,1054],{},[71,1039,1040,1042,1045,1047,1049,1052],{},[471,1041,769],{},[74,1043,1044],{},"40",[78,1046,969],{},[471,1048,972],{},[74,1050,1051],{},"75",[78,1053,978],{},[82,1055,1056],{"encoding":84},"-40\\text{ °C to }+75\\text{ °C}",[55,1058,1060,1087],{"className":1059,"ariaHidden":90},[89],[55,1061,1063,1066,1069,1072,1078,1081,1084],{"className":1062},[94],[55,1064],{"className":1065,"style":991},[98],[55,1067,769],{"className":1068},[103],[55,1070,1044],{"className":1071},[103],[55,1073,1075],{"className":1074},[103,107],[55,1076,969],{"className":1077},[103],[55,1079],{"className":1080,"style":816},[513],[55,1082,972],{"className":1083},[820],[55,1085],{"className":1086,"style":816},[513],[55,1088,1090,1093,1096],{"className":1089},[94],[55,1091],{"className":1092,"style":160},[98],[55,1094,1051],{"className":1095},[103],[55,1097,1099],{"className":1098},[103,107],[55,1100,978],{"className":1101},[103]," for -T model)",[270,1104,1105,1110],{},[286,1106,1107],{"align":275},[29,1108,1109],{},"Enclosure Dimensions",[286,1111,1112,901,1199,1285],{"align":275},[55,1113,1115,1144],{"className":1114},[58],[55,1116,1118],{"className":1117},[62],[64,1119,1120],{"xmlns":66},[68,1121,1122,1141],{},[71,1123,1124,1127,1130,1133,1135,1138],{},[74,1125,1126],{},"79.2",[471,1128,1129],{},"×",[74,1131,1132],{},"135",[471,1134,1129],{},[74,1136,1137],{},"137",[78,1139,1140],{}," mm",[82,1142,1143],{"encoding":84},"79.2\\times 135\\times 137\\text{ mm}",[55,1145,1147,1166,1184],{"className":1146,"ariaHidden":90},[89],[55,1148,1150,1154,1157,1160,1163],{"className":1149},[94],[55,1151],{"className":1152,"style":1153},[98],"height:0.7278em;vertical-align:-0.0833em;",[55,1155,1126],{"className":1156},[103],[55,1158],{"className":1159,"style":816},[513],[55,1161,1129],{"className":1162},[820],[55,1164],{"className":1165,"style":816},[513],[55,1167,1169,1172,1175,1178,1181],{"className":1168},[94],[55,1170],{"className":1171,"style":1153},[98],[55,1173,1132],{"className":1174},[103],[55,1176],{"className":1177,"style":816},[513],[55,1179,1129],{"className":1180},[820],[55,1182],{"className":1183,"style":816},[513],[55,1185,1187,1190,1193],{"className":1186},[94],[55,1188],{"className":1189,"style":99},[98],[55,1191,1137],{"className":1192},[103],[55,1194,1196],{"className":1195},[103,107],[55,1197,1140],{"className":1198},[103],[55,1200,1202,1230],{"className":1201},[58],[55,1203,1205],{"className":1204},[62],[64,1206,1207],{"xmlns":66},[68,1208,1209,1227],{},[71,1210,1211,1214,1216,1219,1221,1224],{},[74,1212,1213],{},"3.1",[471,1215,1129],{},[74,1217,1218],{},"5.3",[471,1220,1129],{},[74,1222,1223],{},"5.4",[78,1225,1226],{}," in",[82,1228,1229],{"encoding":84},"3.1\\times 5.3\\times 5.4\\text{ in}",[55,1231,1233,1251,1269],{"className":1232,"ariaHidden":90},[89],[55,1234,1236,1239,1242,1245,1248],{"className":1235},[94],[55,1237],{"className":1238,"style":1153},[98],[55,1240,1213],{"className":1241},[103],[55,1243],{"className":1244,"style":816},[513],[55,1246,1129],{"className":1247},[820],[55,1249],{"className":1250,"style":816},[513],[55,1252,1254,1257,1260,1263,1266],{"className":1253},[94],[55,1255],{"className":1256,"style":1153},[98],[55,1258,1218],{"className":1259},[103],[55,1261],{"className":1262,"style":816},[513],[55,1264,1129],{"className":1265},[820],[55,1267],{"className":1268,"style":816},[513],[55,1270,1272,1276,1279],{"className":1271},[94],[55,1273],{"className":1274,"style":1275},[98],"height:0.6679em;",[55,1277,1223],{"className":1278},[103],[55,1280,1282],{"className":1281},[103,107],[55,1283,1226],{"className":1284},[103],")",[270,1287,1288,1293],{},[286,1289,1290],{"align":275},[29,1291,1292],{},"Weight and Ingress Rating",[286,1294,1295,901,1335,1285],{"align":275},[55,1296,1298,1316],{"className":1297},[58],[55,1299,1301],{"className":1300},[62],[64,1302,1303],{"xmlns":66},[68,1304,1305,1313],{},[71,1306,1307,1310],{},[74,1308,1309],{},"1440",[78,1311,1312],{}," g",[82,1314,1315],{"encoding":84},"1440\\text{ g}",[55,1317,1319],{"className":1318,"ariaHidden":90},[89],[55,1320,1322,1326,1329],{"className":1321},[94],[55,1323],{"className":1324,"style":1325},[98],"height:0.8389em;vertical-align:-0.1944em;",[55,1327,1309],{"className":1328},[103],[55,1330,1332],{"className":1331},[103,107],[55,1333,1312],{"className":1334},[103],[55,1336,1338,1356],{"className":1337},[58],[55,1339,1341],{"className":1340},[62],[64,1342,1343],{"xmlns":66},[68,1344,1345,1353],{},[71,1346,1347,1350],{},[74,1348,1349],{},"3.18",[78,1351,1352],{}," lb",[82,1354,1355],{"encoding":84},"3.18\\text{ lb}",[55,1357,1359],{"className":1358,"ariaHidden":90},[89],[55,1360,1362,1365,1368],{"className":1361},[94],[55,1363],{"className":1364,"style":160},[98],[55,1366,1349],{"className":1367},[103],[55,1369,1371],{"className":1370},[103,107],[55,1372,1352],{"className":1373},[103],[250,1375],{},[34,1377,1379],{"id":1378},"target-industry-applications","Target Industry Applications",[1381,1382,1383,1391],"card-group",{},[1384,1385,1388],"card",{"icon":1386,"title":1387},"i-lucide-activity","Factory Control Room Backbones",[25,1389,1390],{},"Protects high-volume DCS automation signals against electromagnetic field interference in dense motor cabinets.",[1384,1392,1395],{"icon":1393,"title":1394},"i-lucide-zap","Substation and Power Grid Distribution",[25,1396,1397],{},"Delivers high ESD and surge protection for digital power substation telemetry and real-time monitoring.",[250,1399],{},[34,1401,1403],{"id":1402},"external-resources-and-documentation","External Resources and Documentation",[25,1405,1406],{},"Access official hardware manuals, datasheets, and firmware tools from Moxa:",[1381,1408,1409,1415],{},[1384,1410,1412],{"icon":10,"title":1411,"target":12,"to":11},"Official Moxa EDS-G508E Portal",[25,1413,1414],{},"Download firmware updates, MIB files, and official CAD drawings directly from Moxa.",[1384,1416,1420],{"icon":1417,"title":1418,"target":12,"to":1419},"i-lucide-file-text","Moxa EDS-G508E Series Datasheet","https:\u002F\u002Fwww.moxa.com\u002Fgetmedia\u002F32c7a490-8f76-4bea-bba8-53f5d881bbdf\u002Fmoxa-eds-g508e-series-datasheet-v1.3.pdf",[25,1421,1422],{},"Review complete EMC immunity test reports, ordering options, and accessory compatibility tables.",{"title":1424,"searchDepth":1425,"depth":1425,"links":1426},"",3,[1427,1429,1430,1431],{"id":36,"depth":1428,"text":37},2,{"id":254,"depth":1428,"text":255},{"id":1378,"depth":1428,"text":1379},{"id":1402,"depth":1428,"text":1403},"Industrial Networking and Managed Switches","Hardened Layer 2 and Layer 3 managed Ethernet switches engineered for high electromagnetic interference and mission-critical automation loops.",[1435,1436,1437,1438],"Moxa MXstudio Network Management Suite and MXview One Platform","Moxa ABC-02-USB Automatic Backup Configurator","Standard EtherNet\u002FIP, PROFINET, and Modbus TCP Controllers","Standard 35 mm DIN Rail and Wall Mounting Systems","USD","2026-09-26T00:00:00Z","Rugged 8-port full Gigabit Layer 2 managed Ethernet switch featuring heavy electromagnetic noise immunity and millisecond-level network redundancy for industrial control rooms.",[1443,1449],{"name":1444,"url":1445,"type":1446,"format":1447,"size":1448},"Moxa EDS-G508E Series Official Datasheet","\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fdatasheet-moxa-eds-g508e.pdf","Datasheet","pdf","1.4 MB",{"name":1450,"url":1451,"type":1452,"format":1447,"size":1453},"Moxa EDS-G508E Hardware Installation Manual","\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fmanual-moxa-eds-g508e.pdf","Manual","4.8 MB",false,"md",[1457,1461],{"src":1458,"alt":1459,"caption":1460},"\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fgallery-1.png","Moxa EDS-G508E full front panel layout with status LEDs and 8 Gigabit RJ45 ports","Heavy-duty IP30 metal enclosure with 8 Gigabit RJ45 ports, USB console, and system status indicators",{"src":1462,"alt":1463,"caption":1464},"\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fgallery-2.png","Moxa EDS-G508E mounted on a DIN rail inside an industrial control enclosure","Compact DIN rail footprint featuring redundant terminal block power inputs and relay contact alarms",[1466,1467,1468,1469,1470,1471],"8 full Gigabit 10\u002F100\u002F1000BaseT(X) Ethernet ports for high-bandwidth backbone automation","Heavy electromagnetic noise immunity compliant with EN 61000-6-2 and IEC 61000-4 EMS standards","Redundant network topologies with Turbo Ring and Turbo Chain (recovery time under 50 ms at 250 switches)","Cybersecurity features based on IEC 62443 standards with RADIUS, TACACS+, MAC ACL, and HTTPS\u002FSSH support","Seamless integration into industrial automation networks via native EtherNet\u002FIP, PROFINET, and Modbus TCP","Flexible dual power inputs (12\u002F24\u002F48\u002F-48 VDC) with reverse polarity and overload current protection","\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e\u002Fimage.png",true,"2026-10-01T07:41:00Z",{"readingTime":1476},{"text":1477,"minutes":1478,"time":1479,"words":1480},"2 min read",1.9,114000,380,"\u002Fstore\u002Fnetworking\u002Fmoxa-eds-g508e",{"title":1483,"description":1484},"Moxa EDS-G508E 8-Port Gigabit Managed Switch | NodeWave","Explore the Moxa EDS-G508E Managed Switch. Featuring 8 full Gigabit ports, heavy EMC shielding, Turbo Ring redundancy, and IEC 62443 cyber protection.","MOXA-EDS-G508E",[1487,1491,1494,1497,1501,1504,1507,1511,1514,1518,1521,1524],{"category":1488,"label":1489,"value":1490},"Port and Interface Configuration","Gigabit Ethernet Ports","8x 10\u002F100\u002F1000BaseT(X) RJ45 auto-negotiation ports",{"category":1488,"label":1492,"value":1493},"Console and Storage Ports","1x USB-serial console (Type-B), 1x USB Type-A configuration port",{"category":1488,"label":1495,"value":1496},"Alarm and Digital Input","1x Relay output (1 A @ 24 VDC), 1x Digital Input (+13 to +30 V for State 1)",{"category":1498,"label":1499,"value":1500},"Software and Network Security","Redundancy Protocols","Turbo Ring v1\u002Fv2, Turbo Chain, RSTP\u002FSTP, MSTP, Link Aggregation",{"category":1498,"label":1502,"value":1503},"Industrial Protocols","EtherNet\u002FIP, PROFINET IO Device, Modbus TCP",{"category":1498,"label":1505,"value":1506},"Security Features","IEEE 802.1X, RADIUS, TACACS+, MAC ACL, HTTPS, SSH, SNMPv3, Sticky MAC",{"category":1508,"label":1509,"value":1510},"EMC and Heavy Industrial Shielding","EMI Compliance","CISPR 32, FCC Part 15B Class A",{"category":1508,"label":1512,"value":1513},"EMS Immunity Standards","IEC 61000-4-2 (ESD 15kV), IEC 61000-4-3 (RS 10V\u002Fm), IEC 61000-4-4 (EFT 4kV), IEC 61000-4-5 (Surge 4kV)",{"category":1515,"label":1516,"value":1517},"Power and Mechanical Specifications","Input Power Range","12 \u002F 24 \u002F 48 \u002F -48 VDC redundant dual inputs (Operating voltage 9.6 to 60 VDC)",{"category":1515,"label":1519,"value":1520},"Power Consumption","0.28 A @ 24 VDC (0.37 A max)",{"category":1515,"label":1522,"value":1523},"Dimensions and Weight","79.2 x 135 x 137 mm (3.1 x 5.3 x 5.4 in) | 1440 g (3.18 lb)",{"category":1515,"label":1525,"value":1526,"unit":1527},"Operating Temperature","-10 to +60","°C","store\u002Fnetworking\u002Fmoxa-eds-g508e",[1530,1531,1532,1533,1534,1535],"Moxa","EDS-G508E","Managed Switch","Gigabit Ethernet","Industrial EMC Shielding","Turbo Ring",[1537,1538,1539,1540],"Factory Control Room Network Signal Isolation and High-EMC Environments","Power Substation Control and Distributed Control Systems (DCS)","Intelligent Transportation Systems (ITS) and Real-Time Video Surveillance Backbone","Water Treatment Plant High-Availability Ring Networks","tyehtD8VL6MfryrpwML8KhRCQibCkSazxt9A0Pm1vcg",[1543,1548],{"title":1544,"path":1545,"stem":1546,"description":1547,"children":-1},"Hirschmann Ethernet-APL & Fiber Industrial Switches","\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch","store\u002Fnetworking\u002Fhirschmann-apl-switch","Premium fiber-uplink and Ethernet-APL field switches engineered by Belden Hirschmann for high-integrity loop routing and intrinsically safe hazardous explosion-proof zones.",{"title":1549,"path":1550,"stem":1551,"description":1552,"children":-1},"Bosch MIC IP Fusion 9000i Extreme Environment PTZ Camera","\u002Fstore\u002Fsurveillance\u002Fbosch-mic-fusion-9000i","store\u002Fsurveillance\u002Fbosch-mic-fusion-9000i","Ultra-rugged dual bispectral PTZ camera fusing optical Starlight imaging and uncooled thermal detection for critical infrastructure and perimeter security.",[1554,2512],{"id":1555,"title":1556,"_path":6,"anchors":1557,"badge":1564,"body":1565,"category":1432,"categoryDescription":1433,"categoryIcon":118,"compareAtPrice":6,"compatibility":2423,"currency":1439,"date":1440,"description":2428,"downloads":2429,"draft":1454,"excerpt":6,"extension":1455,"featured":1454,"gallery":2438,"highlights":2447,"image":2454,"inStock":1473,"lastUpdated":2455,"meta":2456,"navigation":1473,"path":2462,"price":6,"seo":2463,"sku":2466,"specs":2467,"stem":2501,"tags":2502,"useCases":2506,"version":6,"__hash__":2511},"store\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400.md","Cisco Catalyst IE3400 Heavy Duty Switch",[1558,1561],{"label":1559,"icon":10,"to":1560,"target":12},"Official Cisco Catalyst IE3400 Product Page","https:\u002F\u002Fwww.cisco.com\u002Fc\u002Fen\u002Fus\u002Fproducts\u002Fswitches\u002Fcatalyst-ie3400-rugged-series-switches\u002Findex.html",{"label":1562,"icon":15,"to":1563,"target":12},"Cisco Industrial Ethernet Switch Portfolio","https:\u002F\u002Fwww.cisco.com\u002Fc\u002Fen\u002Fus\u002Fproducts\u002Fswitches\u002Findustrial-ethernet-switches\u002Findex.html","DCS Backbone Ready",{"type":19,"value":1566,"toc":2417},[1567,1582,1584,1630,1638,1848,1850,1852,2377,2379,2381,2395,2397,2399,2402],[22,1568,1569],{},[25,1570,27,1571,1573,1574,1577,1578,1581],{},[29,1572,1556],{}," is built for mission-critical ",[29,1575,1576],{},"Distributed Control System (DCS)\nplatforms",". Running ",[29,1579,1580],{},"Cisco IOS XE",", this modular DIN-rail switch provides full Gigabit performance, ultra-low\nlatency, and up to 26 high-density ports to prevent signal bottlenecks across automated plant environments.",[34,1583,37],{"id":36},[25,1585,27,1586,1589,1590,1629],{},[29,1587,1588],{},"Cisco Catalyst IE3400 Rugged Series"," brings intent-based enterprise networking directly to severe factory floor\nenvironments. Designed with modular expansion capabilities, the IE3400 scales up to 26 Gigabit ports and supports\nhigh-density Power over Ethernet Plus (PoE+) up to ",[55,1591,1593,1611],{"className":1592},[58],[55,1594,1596],{"className":1595},[62],[64,1597,1598],{"xmlns":66},[68,1599,1600,1608],{},[71,1601,1602,1605],{},[74,1603,1604],{},"480",[78,1606,1607],{}," W",[82,1609,1610],{"encoding":84},"480\\text{ W}",[55,1612,1614],{"className":1613,"ariaHidden":90},[89],[55,1615,1617,1620,1623],{"className":1616},[94],[55,1618],{"className":1619,"style":226},[98],[55,1621,1604],{"className":1622},[103],[55,1624,1626],{"className":1625},[103,107],[55,1627,1607],{"className":1628},[103],", delivering non-blocking line-rate performance for\ndeterministic DCS communications.",[44,1631,1632],{"color":46,"icon":47},[25,1633,1634,1637],{},[29,1635,1636],{},"Enterprise Policy at the Edge:"," By running Cisco IOS XE, the IE3400 extends security policies, Cisco Catalyst Center\n(DNA Center) automation, and zero-trust port isolation directly to field-level I\u002FO racks and DCS controllers.",[113,1639,1640,1662],{},[116,1641,1642],{"icon":118,"label":119},[121,1643,1644,1650,1656],{},[124,1645,1646,1649],{},[29,1647,1648],{},"High-Density Modular Expansion:"," Expand from a compact 10-port base system up to 26 ports using copper, SFP fiber,\nor PoE+ expansion modules.",[124,1651,1652,1655],{},[29,1653,1654],{},"Ultra-Low Latency Determinism:"," Supports IEEE 1588v2 Precision Time Protocol (PTP), CIP EtherNet\u002FIP, and PROFINET\nQoS for real-time fieldbus synchronization.",[124,1657,1658,1661],{},[29,1659,1660],{},"Resilient Ring Failover:"," Features Cisco Resilient Ethernet Protocol (REP) and Spanning Tree protocols (MSTP\u002FRSTP)\nfor sub-second network link recovery.",[116,1663,1664,1754],{"icon":185,"label":186},[25,1665,1666,1667,1709,1710,1753],{},"The IE3400 utilizes a fanless, convection-cooled aluminum enclosure designed for extreme operating conditions\nbetween ",[55,1668,1670,1688],{"className":1669},[58],[55,1671,1673],{"className":1672},[62],[64,1674,1675],{"xmlns":66},[68,1676,1677,1685],{},[71,1678,1679,1681,1683],{},[471,1680,769],{},[74,1682,1044],{},[78,1684,978],{},[82,1686,1687],{"encoding":84},"-40\\text{ °C}",[55,1689,1691],{"className":1690,"ariaHidden":90},[89],[55,1692,1694,1697,1700,1703],{"className":1693},[94],[55,1695],{"className":1696,"style":991},[98],[55,1698,769],{"className":1699},[103],[55,1701,1044],{"className":1702},[103],[55,1704,1706],{"className":1705},[103,107],[55,1707,978],{"className":1708},[103]," and ",[55,1711,1713,1732],{"className":1712},[58],[55,1714,1716],{"className":1715},[62],[64,1717,1718],{"xmlns":66},[68,1719,1720,1729],{},[71,1721,1722,1724,1727],{},[471,1723,972],{},[74,1725,1726],{},"70",[78,1728,978],{},[82,1730,1731],{"encoding":84},"+70\\text{ °C}",[55,1733,1735],{"className":1734,"ariaHidden":90},[89],[55,1736,1738,1741,1744,1747],{"className":1737},[94],[55,1739],{"className":1740,"style":991},[98],[55,1742,972],{"className":1743},[103],[55,1745,1726],{"className":1746},[103],[55,1748,1750],{"className":1749},[103,107],[55,1751,978],{"className":1752},[103],". The base system packs eight Gigabit RJ45 downlinks and two Gigabit SFP\nuplink slots.",[25,1755,1756,1757,1795,1796,1847],{},"Equipped with ",[55,1758,1760,1777],{"className":1759},[58],[55,1761,1763],{"className":1762},[62],[64,1764,1765],{"xmlns":66},[68,1766,1767,1774],{},[71,1768,1769,1771],{},[74,1770,562],{},[78,1772,1773],{}," GB",[82,1775,1776],{"encoding":84},"4\\text{ GB}",[55,1778,1780],{"className":1779,"ariaHidden":90},[89],[55,1781,1783,1786,1789],{"className":1782},[94],[55,1784],{"className":1785,"style":226},[98],[55,1787,562],{"className":1788},[103],[55,1790,1792],{"className":1791},[103,107],[55,1793,1773],{"className":1794},[103]," DRAM, hardware-based Secure Unique Device Identifier (SUDI) chips, and dual terminal blocks\nfor ",[55,1797,1799,1820],{"className":1798},[58],[55,1800,1802],{"className":1801},[62],[64,1803,1804],{"xmlns":66},[68,1805,1806,1817],{},[71,1807,1808,1811,1813,1815],{},[74,1809,1810],{},"9.6",[78,1812,207],{},[74,1814,975],{},[78,1816,213],{},[82,1818,1819],{"encoding":84},"9.6\\text{ to }60\\text{ VDC}",[55,1821,1823],{"className":1822,"ariaHidden":90},[89],[55,1824,1826,1829,1832,1838,1841],{"className":1825},[94],[55,1827],{"className":1828,"style":226},[98],[55,1830,1810],{"className":1831},[103],[55,1833,1835],{"className":1834},[103,107],[55,1836,207],{"className":1837},[103],[55,1839,975],{"className":1840},[103],[55,1842,1844],{"className":1843},[103,107],[55,1845,213],{"className":1846},[103]," power inputs, the switch provides zero-downtime operation for demanding industrial\narchitectures.",[250,1849],{},[34,1851,255],{"id":254},[257,1853,1854,1919,1985],{},[260,1855,1857],{"label":1856},"Switching Performance and OS",[264,1858,1859,1867],{},[267,1860,1861],{},[270,1862,1863,1865],{},[273,1864,276],{"align":275},[273,1866,279],{"align":275},[281,1868,1869,1879,1889,1899,1909],{},[270,1870,1871,1876],{},[286,1872,1873],{"align":275},[29,1874,1875],{},"System Operating System",[286,1877,1878],{"align":275},"Cisco IOS XE (Network Essentials or Network Advantage)",[270,1880,1881,1886],{},[286,1882,1883],{"align":275},[29,1884,1885],{},"Base Port Setup",[286,1887,1888],{"align":275},"8x 10\u002F100\u002F1000 Mbps RJ45 ports + 2x 100\u002F1000 SFP uplinks",[270,1890,1891,1896],{},[286,1892,1893],{"align":275},[29,1894,1895],{},"Maximum System Capacity",[286,1897,1898],{"align":275},"Up to 26 Gigabit Ethernet ports via 1 expansion module",[270,1900,1901,1906],{},[286,1902,1903],{"align":275},[29,1904,1905],{},"PoE Capability",[286,1907,1908],{"align":275},"Up to 24 ports PoE\u002FPoE+ (30 W per port, 480 W max budget)",[270,1910,1911,1916],{},[286,1912,1913],{"align":275},[29,1914,1915],{},"System Memory",[286,1917,1918],{"align":275},"4 GB DRAM",[260,1920,1922],{"label":1921},"Industrial Features and Security",[264,1923,1924,1934],{},[267,1925,1926],{},[270,1927,1928,1931],{},[273,1929,1930],{"align":275},"Feature",[273,1932,1933],{"align":275},"Standard Support",[281,1935,1936,1945,1955,1965,1975],{},[270,1937,1938,1942],{},[286,1939,1940],{"align":275},[29,1941,1502],{},[286,1943,1944],{"align":275},"CIP EtherNet\u002FIP, PROFINET v2, Modbus TCP, GOOSE messaging",[270,1946,1947,1952],{},[286,1948,1949],{"align":275},[29,1950,1951],{},"Precision Timing",[286,1953,1954],{"align":275},"IEEE 1588v2 PTP (Precision Time Protocol)",[270,1956,1957,1962],{},[286,1958,1959],{"align":275},[29,1960,1961],{},"Cybersecurity Baseline",[286,1963,1964],{"align":275},"IEEE 802.1X, MACsec, Port Security, TACACS+, RADIUS, SUDI 2099",[270,1966,1967,1972],{},[286,1968,1969],{"align":275},[29,1970,1971],{},"Network Visibility",[286,1973,1974],{"align":275},"Flexible NetFlow (FNF), SPAN\u002FRSPAN, SNMPv3, Syslog",[270,1976,1977,1982],{},[286,1978,1979],{"align":275},[29,1980,1981],{},"Management Platforms",[286,1983,1984],{"align":275},"Cisco Catalyst Center, Cisco Industrial Network Director (IND)",[260,1986,1988],{"label":1987},"Electrical and Environmental",[264,1989,1990,1998],{},[267,1991,1992],{},[270,1993,1994,1996],{},[273,1995,726],{"align":275},[273,1997,729],{"align":275},[281,1999,2000,2062,2143,2192,2367],{},[270,2001,2002,2007],{},[286,2003,2004],{"align":275},[29,2005,2006],{},"Input Voltage Range",[286,2008,2009,2061],{"align":275},[55,2010,2012,2034],{"className":2011},[58],[55,2013,2015],{"className":2014},[62],[64,2016,2017],{"xmlns":66},[68,2018,2019,2031],{},[71,2020,2021,2023,2026,2028],{},[74,2022,1810],{},[78,2024,2025],{}," V to ",[74,2027,975],{},[78,2029,2030],{}," V DC",[82,2032,2033],{"encoding":84},"9.6\\text{ V to }60\\text{ V DC}",[55,2035,2037],{"className":2036,"ariaHidden":90},[89],[55,2038,2040,2043,2046,2052,2055],{"className":2039},[94],[55,2041],{"className":2042,"style":226},[98],[55,2044,1810],{"className":2045},[103],[55,2047,2049],{"className":2048},[103,107],[55,2050,2025],{"className":2051},[103],[55,2053,975],{"className":2054},[103],[55,2056,2058],{"className":2057},[103,107],[55,2059,2030],{"className":2060},[103]," redundant terminal block inputs",[270,2063,2064,2068],{},[286,2065,2066],{"align":275},[29,2067,1525],{},[286,2069,2070,2142],{"align":275},[55,2071,2073,2097],{"className":2072},[58],[55,2074,2076],{"className":2075},[62],[64,2077,2078],{"xmlns":66},[68,2079,2080,2094],{},[71,2081,2082,2084,2086,2088,2090,2092],{},[471,2083,769],{},[74,2085,1044],{},[78,2087,969],{},[471,2089,972],{},[74,2091,1726],{},[78,2093,978],{},[82,2095,2096],{"encoding":84},"-40\\text{ °C to }+70\\text{ °C}",[55,2098,2100,2127],{"className":2099,"ariaHidden":90},[89],[55,2101,2103,2106,2109,2112,2118,2121,2124],{"className":2102},[94],[55,2104],{"className":2105,"style":991},[98],[55,2107,769],{"className":2108},[103],[55,2110,1044],{"className":2111},[103],[55,2113,2115],{"className":2114},[103,107],[55,2116,969],{"className":2117},[103],[55,2119],{"className":2120,"style":816},[513],[55,2122,972],{"className":2123},[820],[55,2125],{"className":2126,"style":816},[513],[55,2128,2130,2133,2136],{"className":2129},[94],[55,2131],{"className":2132,"style":160},[98],[55,2134,1726],{"className":2135},[103],[55,2137,2139],{"className":2138},[103,107],[55,2140,978],{"className":2141},[103]," (Sealed\u002Fvented cabinet certified)",[270,2144,2145,2150],{},[286,2146,2147],{"align":275},[29,2148,2149],{},"Shock and Vibration",[286,2151,2152,2153,2191],{"align":275},"IEC 60068-2-27 (",[55,2154,2156,2173],{"className":2155},[58],[55,2157,2159],{"className":2158},[62],[64,2160,2161],{"xmlns":66},[68,2162,2163,2170],{},[71,2164,2165,2167],{},[74,2166,76],{},[78,2168,2169],{}," G",[82,2171,2172],{"encoding":84},"50\\text{ G}",[55,2174,2176],{"className":2175,"ariaHidden":90},[89],[55,2177,2179,2182,2185],{"className":2178},[94],[55,2180],{"className":2181,"style":226},[98],[55,2183,76],{"className":2184},[103],[55,2186,2188],{"className":2187},[103,107],[55,2189,2169],{"className":2190},[103]," operational shock) \u002F IEC 60068-2-64",[270,2193,2194,2199],{},[286,2195,2196],{"align":275},[29,2197,2198],{},"Dimensions (WxDxH)",[286,2200,2201,901,2284,1285],{"align":275},[55,2202,2204,2230],{"className":2203},[58],[55,2205,2207],{"className":2206},[62],[64,2208,2209],{"xmlns":66},[68,2210,2211,2227],{},[71,2212,2213,2216,2218,2221,2223,2225],{},[74,2214,2215],{},"152",[471,2217,1129],{},[74,2219,2220],{},"91",[471,2222,1129],{},[74,2224,1132],{},[78,2226,1140],{},[82,2228,2229],{"encoding":84},"152\\times 91\\times 135\\text{ mm}",[55,2231,2233,2251,2269],{"className":2232,"ariaHidden":90},[89],[55,2234,2236,2239,2242,2245,2248],{"className":2235},[94],[55,2237],{"className":2238,"style":1153},[98],[55,2240,2215],{"className":2241},[103],[55,2243],{"className":2244,"style":816},[513],[55,2246,1129],{"className":2247},[820],[55,2249],{"className":2250,"style":816},[513],[55,2252,2254,2257,2260,2263,2266],{"className":2253},[94],[55,2255],{"className":2256,"style":1153},[98],[55,2258,2220],{"className":2259},[103],[55,2261],{"className":2262,"style":816},[513],[55,2264,1129],{"className":2265},[820],[55,2267],{"className":2268,"style":816},[513],[55,2270,2272,2275,2278],{"className":2271},[94],[55,2273],{"className":2274,"style":99},[98],[55,2276,1132],{"className":2277},[103],[55,2279,2281],{"className":2280},[103,107],[55,2282,1140],{"className":2283},[103],[55,2285,2287,2313],{"className":2286},[58],[55,2288,2290],{"className":2289},[62],[64,2291,2292],{"xmlns":66},[68,2293,2294,2310],{},[71,2295,2296,2299,2301,2304,2306,2308],{},[74,2297,2298],{},"6.0",[471,2300,1129],{},[74,2302,2303],{},"3.6",[471,2305,1129],{},[74,2307,1218],{},[78,2309,1226],{},[82,2311,2312],{"encoding":84},"6.0\\times 3.6\\times 5.3\\text{ in}",[55,2314,2316,2334,2352],{"className":2315,"ariaHidden":90},[89],[55,2317,2319,2322,2325,2328,2331],{"className":2318},[94],[55,2320],{"className":2321,"style":1153},[98],[55,2323,2298],{"className":2324},[103],[55,2326],{"className":2327,"style":816},[513],[55,2329,1129],{"className":2330},[820],[55,2332],{"className":2333,"style":816},[513],[55,2335,2337,2340,2343,2346,2349],{"className":2336},[94],[55,2338],{"className":2339,"style":1153},[98],[55,2341,2303],{"className":2342},[103],[55,2344],{"className":2345,"style":816},[513],[55,2347,1129],{"className":2348},[820],[55,2350],{"className":2351,"style":816},[513],[55,2353,2355,2358,2361],{"className":2354},[94],[55,2356],{"className":2357,"style":1275},[98],[55,2359,1218],{"className":2360},[103],[55,2362,2364],{"className":2363},[103,107],[55,2365,1226],{"className":2366},[103],[270,2368,2369,2374],{},[286,2370,2371],{"align":275},[29,2372,2373],{},"Compliance",[286,2375,2376],{"align":275},"UL\u002FIEC 61010-2-201, UL\u002FIEC 62368-1, Class I Div 2 \u002F Zone 2",[250,2378],{},[34,2380,1379],{"id":1378},[1381,2382,2383,2389],{},[1384,2384,2386],{"icon":1386,"title":2385},"Plant DCS Infrastructure",[25,2387,2388],{},"Acts as the central, low-latency Gigabit backbone connecting Distributed Control System (DCS) process nodes.",[1384,2390,2392],{"icon":1393,"title":2391},"Substation and Power Automation",[25,2393,2394],{},"Delivers real-time GOOSE messaging and IEEE 1588 time synchronization across high-EMC utility bays.",[250,2396],{},[34,2398,1403],{"id":1402},[25,2400,2401],{},"Access official documentation, datasheets, and software tools directly from Cisco:",[1381,2403,2404,2410],{},[1384,2405,2407],{"icon":10,"title":2406,"target":12,"to":1560},"Official Cisco Catalyst IE3400 Portal",[25,2408,2409],{},"Explore ordering guides, expansion module combinations, and licensing options.",[1384,2411,2414],{"icon":1417,"title":2412,"target":12,"to":2413},"Cisco Catalyst IE3400 Datasheet Document","https:\u002F\u002Fwww.cisco.com\u002Fc\u002Fen\u002Fus\u002Fproducts\u002Fcollateral\u002Fswitches\u002Fcatalyst-ie3400-rugged-series-switches\u002Fdatasheet-c78-741910.html",[25,2415,2416],{},"Review complete technical specifications, power supply guides, and mounting accessories.",{"title":1424,"searchDepth":1425,"depth":1425,"links":2418},[2419,2420,2421,2422],{"id":36,"depth":1428,"text":37},{"id":254,"depth":1428,"text":255},{"id":1378,"depth":1428,"text":1379},{"id":1402,"depth":1428,"text":1403},[2424,2425,2426,2427],"Cisco Catalyst Center (formerly DNA Center) and Cisco Industrial Network Director (IND)","Cisco IEM-3300 and IEM-3400 Series Copper and Fiber Expansion Modules","Standard CIP EtherNet\u002FIP, PROFINET IO, and Modbus TCP Controllers","Standard 35 mm DIN Rail and Wall Mounting Assemblies","High-density modular DIN-rail industrial switch delivering secure, high-bandwidth, and low-latency network backbones for DCS platforms.",[2430,2434],{"name":2431,"url":2432,"type":1446,"format":1447,"size":2433},"Cisco Catalyst IE3400 Series Official Datasheet","\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fdatasheet-cisco-ie3400.pdf","2.1 MB",{"name":2435,"url":2436,"type":1452,"format":1447,"size":2437},"Cisco Catalyst IE3400 Hardware Installation Guide","\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fmanual-cisco-ie3400.pdf","5.8 MB",[2439,2443],{"src":2440,"alt":2441,"caption":2442},"\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fgallery-1.png","Cisco Catalyst IE3400 base unit front panel featuring Gigabit RJ45 ports and SFP uplinks","Ruggedized DIN rail housing featuring full Gigabit throughput and Cisco IOS XE execution",{"src":2444,"alt":2445,"caption":2446},"\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fgallery-2.png","Cisco Catalyst IE3400 extended with an expansion module inside a DCS cabinet","Modular chassis expansion providing up to 26 ports with up to 480 W PoE power budget",[2448,2449,2450,2451,2452,2453],"Modular DIN-rail chassis expandable up to 26 full Gigabit ports with copper and SFP fiber options","Driven by programmable Cisco IOS XE with intent-based networking and automated Cisco DNA Center management","Delivers up to 24 ports of High-Density PoE\u002FPoE+ (30 W per port) with a total power budget up to 480 W","Ultra-low latency determinism certified for CIP EtherNet\u002FIP, PROFINET v2, and IEEE 1588v2 PTP time synchronization","Hardened fanless construction operating reliably across extreme industrial temperatures from -40 °C to 70 °C","Enterprise-grade cybersecurity featuring MACsec, IEEE 802.1X, Trust Anchor, and Flexible NetFlow (FNF)","\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400\u002Fimage.png","2026-10-01T07:46:00Z",{"readingTime":2457},{"text":2458,"minutes":2459,"time":2460,"words":2461},"3 min read",2.085,125100,417,"\u002Fstore\u002Fnetworking\u002Fcisco-catalyst-ie3400",{"title":2464,"description":2465},"Cisco Catalyst IE3400 Heavy Duty Switch | NodeWave","Explore the Cisco Catalyst IE3400 Heavy Duty Switch. Advanced modular DIN-rail switch with full Gigabit speed, Cisco IOS XE, 480W PoE+, and low-latency DCS support.","CSCO-CAT-IE3400",[2468,2472,2475,2478,2481,2485,2488,2492,2495,2497,2499],{"category":2469,"label":2470,"value":2471},"Port and Modular Expansion","Base Port Configuration","8x 10\u002F100\u002F1000Base-T RJ45 ports + 2x 100\u002F1000 SFP uplink slots",{"category":2469,"label":2473,"value":2474},"Maximum Port Capacity","Expandable up to 26 Gigabit ports using 1 expansion module slot",{"category":2469,"label":2476,"value":2477},"Power over Ethernet (PoE)","Up to 24x IEEE 802.3at PoE+ ports (up to 480 W total budget)",{"category":2479,"label":2480,"value":1878},"Performance and Operating Software","Operating System Software",{"category":2482,"label":2483,"value":2484},"Performance and Operating System","Switching Capacity and Memory","Line-rate non-blocking switching | 4 GB DRAM | 2 GB Flash",{"category":2482,"label":2486,"value":2487},"Real-Time Protocols","CIP EtherNet\u002FIP, PROFINET v2, Modbus TCP, IEEE 1588v2 PTP",{"category":2489,"label":2490,"value":2491},"Network Security and Monitoring","Cybersecurity Protocols","MACsec, 802.1X, Port Security, Dynamic ARP Inspection, TACACS+, RADIUS",{"category":2489,"label":2493,"value":2494},"Redundancy Technologies","Resilient Ethernet Protocol (REP) ring, MSTP, RSTP, EtherChannel",{"category":1515,"label":1516,"value":2496},"Dual redundant 9.6 V to 60 V DC input via terminal blocks",{"category":1515,"label":1522,"value":2498},"152 x 91 x 135 mm (6.0 x 3.6 x 5.3 in) | 1.7 kg (3.75 lbs)",{"category":1515,"label":1525,"value":2500,"unit":1527},"-40 to +70","store\u002Fnetworking\u002Fcisco-catalyst-ie3400",[2503,2504,1532,1533,1580,2505],"Cisco","Catalyst IE3400","DCS Platform",[2507,2508,2509,2510],"Distributed Control System (DCS) Plant High-Availability Network Backbones","Power Substation Automation with GOOSE Messaging and IEEE 1588 Precision Timing","High-Density Video Surveillance and Security Camera Deployments","Factory Automation Processing High-Volume Field Loops and Control Networks","9JkVQT-2qsKAY7YGmFmeJkWC6LnHumlhH2pc0YwhOHU",{"id":2513,"title":1544,"_path":6,"anchors":2514,"badge":2521,"body":2522,"category":1432,"categoryDescription":3019,"categoryIcon":118,"compareAtPrice":6,"compatibility":3020,"currency":1439,"date":1440,"description":1547,"downloads":3025,"draft":1454,"excerpt":6,"extension":1455,"featured":1454,"gallery":3034,"highlights":3043,"image":3050,"inStock":1473,"lastUpdated":3051,"meta":3052,"navigation":1473,"path":1545,"price":6,"seo":3057,"sku":3060,"specs":3061,"stem":1546,"tags":3095,"useCases":3102,"version":6,"__hash__":3107},"store\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch.md",[2515,2518],{"label":2516,"icon":10,"to":2517,"target":12},"Official Belden Hirschmann Brand Hub","https:\u002F\u002Fwww.belden.com\u002Fabout\u002Fconnected-brands\u002Fhirschmann",{"label":2519,"icon":15,"to":2520,"target":12},"Belden Industrial Managed Switches Portfolio","https:\u002F\u002Fwww.belden.com\u002Fproducts\u002Findustrial-networking-cybersecurity\u002Fmanaged-switches","Ex Zone & Ethernet-APL Ready",{"type":19,"value":2523,"toc":3013},[2524,2544,2546,2645,2653,2773,2775,2777,2973,2975,2977,2992,2994,2996,2999],[22,2525,2526],{},[25,2527,27,2528,2531,2532,2535,2536,2539,2540,2543],{},[29,2529,2530],{},"Hirschmann Ethernet-APL Field Switches"," (alongside the ",[29,2533,2534],{},"BOBCAT and Managed Modular Series",") extend high-speed\nIP communication directly into ",[29,2537,2538],{},"explosion-proof process environments",". By utilizing ",[29,2541,2542],{},"Ethernet Advanced Physical\nLayer (Ethernet-APL)"," and 10BASE-T1L single-pair technology, these switches eliminate legacy fieldbus gateways in\nhazardous chemical and oil & gas facilities.",[34,2545,37],{"id":36},[25,2547,2548,2549,2588,2589,2644],{},"Engineered by Belden Hirschmann, these switches deliver intrinsically safe communication to Zone 0, 1, and 2 hazardous\nareas. Combining high-speed fiber-optic uplinks with single-pair Ethernet field spurs, they deliver ",[55,2550,2552,2569],{"className":2551},[58],[55,2553,2555],{"className":2554},[62],[64,2556,2557],{"xmlns":66},[68,2558,2559,2566],{},[71,2560,2561,2563],{},[74,2562,476],{},[78,2564,2565],{}," Mbps",[82,2567,2568],{"encoding":84},"10\\text{ Mbps}",[55,2570,2572],{"className":2571,"ariaHidden":90},[89],[55,2573,2575,2579,2582],{"className":2574},[94],[55,2576],{"className":2577,"style":2578},[98],"height:0.8889em;vertical-align:-0.1944em;",[55,2580,476],{"className":2581},[103],[55,2583,2585],{"className":2584},[103,107],[55,2586,2565],{"className":2587},[103],"\nsimultaneous power and data over 2-wire cabling up to ",[55,2590,2592,2615],{"className":2591},[58],[55,2593,2595],{"className":2594},[62],[64,2596,2597],{"xmlns":66},[68,2598,2599,2612],{},[71,2600,2601,2603,2606,2609],{},[74,2602,466],{},[471,2604,2605],{"separator":90},",",[74,2607,2608],{},"000",[78,2610,2611],{}," meters",[82,2613,2614],{"encoding":84},"1,000\\text{ meters}",[55,2616,2618],{"className":2617,"ariaHidden":90},[89],[55,2619,2621,2624,2627,2631,2635,2638],{"className":2620},[94],[55,2622],{"className":2623,"style":1325},[98],[55,2625,466],{"className":2626},[103],[55,2628,2605],{"className":2629},[2630],"mpunct",[55,2632],{"className":2633,"style":2634},[513],"margin-right:0.1667em;",[55,2636,2608],{"className":2637},[103],[55,2639,2641],{"className":2640},[103,107],[55,2642,2611],{"className":2643},[103],", unlocking real-time asset analytics without\nrisking electrical ignition in explosive atmosphere loops.",[44,2646,2647],{"color":46,"icon":47},[25,2648,2649,2652],{},[29,2650,2651],{},"Direct-to-Field IP Digitization:"," Ethernet-APL brings native TCP\u002FIP protocols (PROFINET, EtherNet\u002FIP, HART-IP)\ndirectly to hazardous field instruments in Zone 0, replacing slow 4-20mA analog loops with high-bandwidth diagnostic\nchannels.",[113,2654,2655,2677],{},[116,2656,2657],{"icon":118,"label":119},[121,2658,2659,2665,2671],{},[124,2660,2661,2664],{},[29,2662,2663],{},"Intrinsically Safe Ex Field Spurs:"," Delivers Ex ia \u002F Ex ic field connections, allowing safe hot-swapping and wiring\nof instruments in explosive gas and dust environments.",[124,2666,2667,2670],{},[29,2668,2669],{},"High-Integrity Fiber Backbones:"," Fast SFP\u002FST\u002FSC optical interfaces extend network links across kilometers of\nhigh-EMC plant territory.",[124,2672,2673,2676],{},[29,2674,2675],{},"HiOS Industrial Software:"," Runs Hirschmann HiOS firmware, featuring sub-20 ms HiPER Ring redundancy and\nTime-Sensitive Networking (TSN) for deterministic loop timing.",[116,2678,2679,2766],{"icon":185,"label":186},[25,2680,2681,2682,2723,2724,2765],{},"Housed in ruggedized IP30 or IP67 die-cast aluminum enclosures, the switch features conformal-coated PCB assemblies\nresistant to corrosive gases and thermal extremes ranging from ",[55,2683,2685,2702],{"className":2684},[58],[55,2686,2688],{"className":2687},[62],[64,2689,2690],{"xmlns":66},[68,2691,2692,2700],{},[71,2693,2694,2696,2698],{},[471,2695,769],{},[74,2697,1044],{},[78,2699,978],{},[82,2701,1687],{"encoding":84},[55,2703,2705],{"className":2704,"ariaHidden":90},[89],[55,2706,2708,2711,2714,2717],{"className":2707},[94],[55,2709],{"className":2710,"style":991},[98],[55,2712,769],{"className":2713},[103],[55,2715,1044],{"className":2716},[103],[55,2718,2720],{"className":2719},[103,107],[55,2721,978],{"className":2722},[103]," to ",[55,2725,2727,2744],{"className":2726},[58],[55,2728,2730],{"className":2729},[62],[64,2731,2732],{"xmlns":66},[68,2733,2734,2742],{},[71,2735,2736,2738,2740],{},[471,2737,972],{},[74,2739,1726],{},[78,2741,978],{},[82,2743,1731],{"encoding":84},[55,2745,2747],{"className":2746,"ariaHidden":90},[89],[55,2748,2750,2753,2756,2759],{"className":2749},[94],[55,2751],{"className":2752,"style":991},[98],[55,2754,972],{"className":2755},[103],[55,2757,1726],{"className":2758},[103],[55,2760,2762],{"className":2761},[103,107],[55,2763,978],{"className":2764},[103],".",[25,2767,2768,2769,2772],{},"The architecture provides high isolation between system power supplies, fiber trunk interfaces, and APL field spur\ncircuits. Built-in diagnostic LEDs, relay contact outputs, and integration with ",[29,2770,2771],{},"Hirschmann Industrial HiVision"," allow\nproactive network monitoring from central control rooms.",[250,2774],{},[34,2776,255],{"id":254},[257,2778,2779,2844,2911],{},[260,2780,2782],{"label":2781},"Ethernet-APL and Network Interfaces",[264,2783,2784,2792],{},[267,2785,2786],{},[270,2787,2788,2790],{},[273,2789,276],{"align":275},[273,2791,279],{"align":275},[281,2793,2794,2804,2814,2824,2834],{},[270,2795,2796,2801],{},[286,2797,2798],{"align":275},[29,2799,2800],{},"Field Layer Standard",[286,2802,2803],{"align":275},"Ethernet-APL (10BASE-T1L, IEEE 802.3cg compliant)",[270,2805,2806,2811],{},[286,2807,2808],{"align":275},[29,2809,2810],{},"Field Spur Port Count",[286,2812,2813],{"align":275},"Up to 16x 2-wire SPE ports supporting combined power + data",[270,2815,2816,2821],{},[286,2817,2818],{"align":275},[29,2819,2820],{},"Maximum Spur Length",[286,2822,2823],{"align":275},"Up to 1,000 m (Trunk) \u002F 200 m (Spur) over shielded twisted pair",[270,2825,2826,2831],{},[286,2827,2828],{"align":275},[29,2829,2830],{},"Optical Trunk Ports",[286,2832,2833],{"align":275},"2x or 4x 100\u002F1000 Mbps SFP fiber uplinks (Multimode \u002F Singlemode)",[270,2835,2836,2841],{},[286,2837,2838],{"align":275},[29,2839,2840],{},"Supported Protocols",[286,2842,2843],{"align":275},"PROFINET, EtherNet\u002FIP, HART-IP, OPC UA, Modbus TCP",[260,2845,2847],{"label":2846},"Hazardous Zone and Electrical Ratings",[264,2848,2849,2859],{},[267,2850,2851],{},[270,2852,2853,2856],{},[273,2854,2855],{"align":275},"Standard \u002F Certification",[273,2857,2858],{"align":275},"Certified Protection Level",[281,2860,2861,2871,2881,2891,2901],{},[270,2862,2863,2868],{},[286,2864,2865],{"align":275},[29,2866,2867],{},"Switch Installation Zone",[286,2869,2870],{"align":275},"ATEX \u002F IECEx Zone 2 \u002F Class I Div 2 compliant",[270,2872,2873,2878],{},[286,2874,2875],{"align":275},[29,2876,2877],{},"Field Instrument Zone",[286,2879,2880],{"align":275},"Intrinsically Safe Ex ia \u002F Ex ic for Zones 0, 1, and 2",[270,2882,2883,2888],{},[286,2884,2885],{"align":275},[29,2886,2887],{},"Power Class Support",[286,2889,2890],{"align":275},"Power Class A, B, and C (supporting up to 500 mW Ex ia power)",[270,2892,2893,2898],{},[286,2894,2895],{"align":275},[29,2896,2897],{},"Input Operating Voltage",[286,2899,2900],{"align":275},"Redundant 24 VDC (18 to 30 VDC) terminal block inputs",[270,2902,2903,2908],{},[286,2904,2905],{"align":275},[29,2906,2907],{},"Electromagnetic Immunity",[286,2909,2910],{"align":275},"Exceeds EN 61000-6-2 heavy industrial EMC standards",[260,2912,2914],{"label":2913},"System Software and Redundancy",[264,2915,2916,2924],{},[267,2917,2918],{},[270,2919,2920,2922],{},[273,2921,1930],{"align":275},[273,2923,1933],{"align":275},[281,2925,2926,2936,2945,2955,2964],{},[270,2927,2928,2933],{},[286,2929,2930],{"align":275},[29,2931,2932],{},"System Firmware",[286,2934,2935],{"align":275},"Hirschmann HiOS (High Performance Operating System)",[270,2937,2938,2942],{},[286,2939,2940],{"align":275},[29,2941,1499],{},[286,2943,2944],{"align":275},"HiPER Ring (recovery \u003C 20 ms), MRP, RSTP\u002FSTP, Trunking",[270,2946,2947,2952],{},[286,2948,2949],{"align":275},[29,2950,2951],{},"Time Synchronization",[286,2953,2954],{"align":275},"IEEE 1588v2 Precision Time Protocol (PTP) & TSN support",[270,2956,2957,2961],{},[286,2958,2959],{"align":275},[29,2960,1961],{},[286,2962,2963],{"align":275},"IEC 62443-4-2 compliant, IEEE 802.1X, Encrypted SSH\u002FHTTPS, ACLs",[270,2965,2966,2970],{},[286,2967,2968],{"align":275},[29,2969,1981],{},[286,2971,2972],{"align":275},"Hirschmann Industrial HiVision & Belden Horizon software",[250,2974],{},[34,2976,1379],{"id":1378},[1381,2978,2979,2986],{},[1384,2980,2983],{"icon":2981,"title":2982},"i-lucide-flame","Hazardous Process Plant Field Loops",[25,2984,2985],{},"Routes intrinsically safe 10BASE-T1L loops directly to pressure, flow, and temperature transmitters in Zone 0\u002F1.",[1384,2987,2989],{"icon":1386,"title":2988},"High-Integrity Fiber DCS Networks",[25,2990,2991],{},"Forms a redundant optical backbone bridging field instrumentation clusters back to main DCS control rooms.",[250,2993],{},[34,2995,1403],{"id":1402},[25,2997,2998],{},"Access official manuals, whitepapers, and product guides directly from Belden Hirschmann:",[1381,3000,3001,3007],{},[1384,3002,3004],{"icon":10,"title":3003,"target":12,"to":2517},"Official Belden Hirschmann Portal",[25,3005,3006],{},"Explore the full range of Hirschmann managed switches, APL field devices, and network management tools.",[1384,3008,3010],{"icon":1417,"title":3009,"target":12,"to":2520},"Belden Industrial Managed Switches",[25,3011,3012],{},"Download detailed datasheets, CAD drawings, and firmware updates for BOBCAT and APL field switches.",{"title":1424,"searchDepth":1425,"depth":1425,"links":3014},[3015,3016,3017,3018],{"id":36,"depth":1428,"text":37},{"id":254,"depth":1428,"text":255},{"id":1378,"depth":1428,"text":1379},{"id":1402,"depth":1428,"text":1403},"Hardened Ethernet switches, Ethernet-APL field devices, and media converters designed for hazardous locations and high-reliability process networks.",[3021,3022,3023,3024],"PROFINET, EtherNet\u002FIP, and HART-IP Process Automation Protocols","Hirschmann Industrial HiVision and Belden Horizon Network Management Software","Standard Field Ethernet-APL Field Instruments and Transmitters","Standard 35 mm DIN Rail and Hazardous Enclosure Mounting Assemblies",[3026,3030],{"name":3027,"url":3028,"type":1446,"format":1447,"size":3029},"Hirschmann Ethernet-APL Field Switch Datasheet","\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fdatasheet-hirschmann-apl.pdf","2.8 MB",{"name":3031,"url":3032,"type":1452,"format":1447,"size":3033},"Hirschmann Ethernet-APL Technology Guide","\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fmanual-hirschmann-apl.pdf","6.5 MB",[3035,3039],{"src":3036,"alt":3037,"caption":3038},"\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fgallery-1.png","Hirschmann Ethernet-APL Field Switch mounted inside an explosion-proof terminal housing","Hardened field enclosure supporting intrinsically safe APL spurs for process instrumentation",{"src":3040,"alt":3041,"caption":3042},"\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fgallery-2.png","Hirschmann BOBCAT Managed Fiber Switch front view showing Gigabit SFP uplinks","Compact DIN rail switch featuring multi-gigabit fiber uplinks and HiOS operating system",[3044,3045,3046,3047,3048,3049],"Bridges enterprise Ethernet backbones to field instruments via Ethernet-APL (10BASE-T1L) physical layer","Delivers intrinsically safe (Ex ia \u002F Ex ic) power and data over a single 2-wire shielded twisted pair up to 1,000 m","Certified for hazardous environments including ATEX\u002FIECEx Zone 2 (installation) powering instruments in Zone 0 and 1","High-integrity redundant fiber uplinks utilizing SFP optical interfaces with sub-20 ms HiPER Ring recovery","Powered by Hirschmann HiOS software featuring TSN (Time-Sensitive Networking) and IEC 62443 security","Rugged IP30\u002FIP67 cast-aluminum enclosures resistant to extreme vibration, thermal shock, and corrosive gases","\u002Fstore\u002Fnetworking\u002Fhirschmann-apl-switch\u002Fimage.png","2026-10-01T07:54:00Z",{"readingTime":3053},{"text":2458,"minutes":3054,"time":3055,"words":3056},2.38,142800,476,{"title":3058,"description":3059},"Hirschmann Ethernet-APL & Fiber Industrial Switches | NodeWave","Explore Hirschmann Ethernet-APL and Fiber Industrial Switches. Designed for explosion-proof Ex Zones 0\u002F1\u002F2, 10BASE-T1L loop routing, and HiOS process redundancy.","HIR-APL-BOBCAT-EX",[3062,3066,3069,3072,3076,3079,3082,3085,3088,3091,3094],{"category":3063,"label":3064,"value":3065},"Fieldbus and Network Interfaces","Physical Layer Technology","Ethernet-APL (10BASE-T1L per IEEE 802.3cg) + 100\u002F1000 Mbps Fiber Uplinks",{"category":3063,"label":3067,"value":3068},"Field Spur Output","Up to 16x 2-wire Single-Pair Ethernet (SPE) ports with power over APL",{"category":3063,"label":3070,"value":3071},"Uplink Interfaces","2x or 4x Gigabit SFP\u002FST\u002FSC optical fiber ports (Multimode \u002F Singlemode)",{"category":3073,"label":3074,"value":3075},"Explosion Protection and Certification","Hazardous Area Certification","ATEX \u002F IECEx Zone 2 installation | Field spurs certified Ex ia (Zone 0\u002F1)",{"category":3073,"label":3077,"value":3078},"Intrinsically Safe Power","Power Class A, B, and C support for Ex ia\u002FEx ic field transmitters",{"category":3080,"label":3081,"value":2935},"Operating Software and Security","Switch Firmware",{"category":3080,"label":3083,"value":3084},"Network Redundancy","HiPER Ring, MRP (Media Redundancy Protocol), RSTP, Link Aggregation",{"category":3080,"label":3086,"value":3087},"Cybersecurity Compliance","IEC 62443-4-2 Level 2, IEEE 802.1X, RADIUS, Port Security, Encrypted Management",{"category":1515,"label":3089,"value":3090},"Operating Input Voltage","Redundant 24 VDC (18 to 30 VDC) input via terminal blocks",{"category":1515,"label":3092,"value":3093},"Dimensions and Housing","Heavy-duty IP30 metal \u002F IP67 die-cast aluminum field enclosure",{"category":1515,"label":1525,"value":2500,"unit":1527},[3096,3097,3098,3099,3100,3101],"Hirschmann","Belden","Ethernet-APL","Hazardous Zone","Intrinsically Safe","10BASE-T1L",[3103,3104,3105,3106],"Chemical and Petrochemical Process Control Field Loop Communications","Explosion-Proof Hazardous Zone (Zone 0\u002F1\u002F2) Process Instrumentation Routing","Pharmaceutical Cleanroom and Distillation Plant Network Backbones","Offshore Platform and Marine Oil & Gas Infrastructure Monitoring","xn8Hivi4i77k71wRisIDix0FTmjpdPn0-M08-uBq2r4",1791086643423]